53
GB
TECHNICAL INFORMATION
INFORMATION LABEL
This gas fireplace is tested and certified for use in several countries. The gas fireplace has been tested for use
with natural gas, LPG and biogas.
Product ID: 2575DM29341
Produced for:
ATTIKA FEUER AG, Brunnmatt 16, CH-6330 Cham / RAIS A/S, Industrivej 20, DK-9900 Frederikshavn
Produced at:
RAIS A/S, Industrivej 20, 9900 Frederikshavn, Danmark
18
2575
Visio Gas 100 F
Visio Gas 100 LC
Visio Gas 100 RC
Visio Gas 100 3S
(VISIO 8)
0359
C
11
C
31
C
91
Gas category and supply pressure
Input
(Hi, kW)
Output
(Hi, kW)
Burner
pressure high
(Hot)
Country of destination
L
P
G
I3+ (28-30/37)
G30@28-30
mbar
11,7
9,4
27,2
Interval
24,5 - 29,6
BE, CH, CY, CZ, ES, FR, GB,
GR, IE, IT, PT, SI, SK, TR
I3+ (28-30/37)
G31@37 mbar
11,2
8,9
36
32,4 - 39,6
BE, CH, CY, CZ, ES, FR, GB,
GR, IE, IT, PT, SI, SK, TR
I3P (30)
G31@30 mbar
9,9
7,9
28
25,2 - 30,8
FI, NL, RO
I3P (37)
G31@37 mbar
11,2
8.9
36
32,4 - 39,6
BE, CH, CZ, ES, FR, GB, GR,
HR, IE, IT, LT, NL, PL, PT, SL,
SK, TR
I3P (50)
G31@50 mbar
11,2
8,9
36
32,4 - 39,6
AT, CH, CZ, DE, NL, SK
I3B/P (30)
G30@30 mbar
11,7
9,4
27,2
24,5 - 29,6
BE, BG, CY, DK, EE, FI, FR,
GB, GR, HR, HU, IT, LT, MT,
NL, NO, RO, SE, SI, SK, TR
I3B/P (30)
G31@30 mbar
9,9
7,9
28
25,2 - 30,8
BE, BG, CY, DK, EE, FI, FR,
GB, GR, HR, HU, IT, LT, MT,
NL, NO, RO, SE, SI, SK, TR
I3B/P (50)
G30/G31@50
11,2
8,9
36
32,4 - 39,6
AT, CH, CZ, DE, FR, SK
N
A
T
U
R
A
L
G
A
S
I2H/
I2E
G20 @ 20 mbar
10,3
8,3
18,6
Interval
16,7 - 20,5
AT, CH, CZ, DE, DK, EE, ES,
FI, GB, GR, HR, IE, IT, LT, LU,
LV, NO, PL, PT, RO, SE, SI,
SK, TR
I2ELL
G25 @ 20 mbar
8,3
6,7
18,5
16,7 - 20,4
DE
I2E+
G20@20 mbar
10,3
8,3
18,6
16,7 - 20,5
BE, FR
I2E+
G25@25 mbar
9,3
7,5
22
19,8 - 24,2
BE, FR
I2L / I2EK / I2
(43.46-45.3 MJ/m3 0c)
G25.3 @ 25 mbar
9,4
7,6
21,5
19,4 - 23,7
NL
TOWN GAS
G150.1 @ 8 mbar
5,9
4,4
4,4
Interval
4 - 4,8
DK, SE
G150.1 @ 10 mbar
6,9
5,3
5,3
4,8 - 5,8
DK, SE
This appliance must be installed in accordance with the rules in force, and only used in a sufficiently ventilated space. Consult
instructions before installation and use of this appliance. Tested and Certified for use on Biopropane. Efficiency class 1.
Serial number
Burner ID.
CE Label for:
Visio Gas 22-06-2023