1

W415-0379 / B / 08.03.05

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031

www.napoleonfireplaces.com • [email protected]

CERTIFIED UNDER AMERICAN NATIONAL STANDARDS, ANSI Z21.11.2, VOLUME II FOR UNVENTED ROOM HEATERS.

UNVENTED MILLIVOLT SYSTEM

INSTALLATION AND OPERATION INSTRUCTIONS FOR

UNVENTED GAS FIREPLACE - GVF42

NATURAL GAS 

 MODEL

 

GVF42N

PROPANE GAS  

MODEL

 

GVF42P

CERTIFIED FOR UNITED STATES USING ANSI METHODS

WARNING: 

 If the information in these instructions is not followed exactly, a fire or

explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapours and liquids in the vicinity

of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

•  Do not try to light any appliance.
•  Do not touch any electrical switch.
•  Do not use any phone in your build-
ing.

•  Immediately call your gas supplier from

a neighbour's phone. Follow the gas
supplier's instructions.

•  If you cannot reach your gas supplier,

call the fire department.

Installation and service must be performed by a qualified installer, service agency or
the gas supplier.

This is an unvented gas-fired heater that uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.

Summary of Contents for GVF42N

Page 1: ...exactly a fire or explosion may result causing property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or a...

Page 2: ...oung children and animals away when the fireplace is hot Due to high temperatures the heater should be located out of traffic and away from furniture and draperies Clothing or other flammable material...

Page 3: ...d company official Labour costs to the account of the prior approval of an authorized company official Labour costs to the account of the prior approval of an authorized company official Labour costs...

Page 4: ...the current ANSI NFPA 70 NATIONAL ELECTRICAL CODE in the United States Suitable for mobile home installation where the mobile home has been permanently placed on its site This heater must not be insta...

Page 5: ...d ventilation air Add the Btu hr of all fuel burning appliances located within the space such as gas furnace gas water heater etc Do not include direct vent gas appliances which draw their input and o...

Page 6: ...he outside atmos phere have a continuous water vapour retarder with a rating of 1 perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and b Weather stripping has been added on ope...

Page 7: ...ide wall of a home This will ensure that clearance to combustibles is maintained within the cavity It is not necessary to install a hearth extension with this fireplace system When roughing in the fir...

Page 8: ...that the front face is offset with the front edge of the corner post approx Centre the nailing tab vertically on the corner post Figure 8 a Drill through the centre of the top and bottom slots in the...

Page 9: ...ck the burner ports Blocked burner ports can cause an incorrect flame pattern carbon deposits and delayed ignition PHAZERTM logs glow when exposed to direct flame 4 Place the bottom of the left crosso...

Page 10: ...re the hood using the screws removed in step 1 Ensure that the louvre brackets are positioned in front of the hood CURTAIN MESH SCREWS HOOD CURTAIN MESH FIGURES 12 a c The curtain mesh must be kept fu...

Page 11: ...17 UPPER LOUVRES Insert the louvre tabs into the slots located at the top left and right corners of the unit SLOT TAB A LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left a...

Page 12: ...nto the clip C and up against the threaded stud B at the other end The blower must be able to be positioned entirely onto the pad Tilt the blower onto its side Slide it past the controls and into the...

Page 13: ...IGURE27 This optional kit is meant to be used only in conjunction with the GD65 Fan Kit which may be ordered from your Wolf Steel Napoleon dealer With the thermostatic sensor option the fan when turne...

Page 14: ...T FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLO SION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE GAS KNOB OXYGEN DEPLETION SENSOR If heater shuts off do not relight until yo...

Page 15: ...IREPLACE CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servic ing This heater should be...

Page 16: ...R NATURAL GAS 28 GD825P VALVE REGULATOR PROPANE 29 W500 0033 VARIABLE SPEED SWITCH WALL MOUNTING PLATE 30 GZ550 KT BLOWER KIT 31 GD65 FAN KIT 32 GD36 THERMOSTATIC SENSOR CONTROL KIT FOR USE WITH GD65...

Page 17: ...l System is not correctly purged purge the gas line Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace Oxygen Depletion Sensor System test and...

Page 18: ...n main burner comes on when gas knob is turned to ON po sition Wall switch is mounted up side down reverse Faulty valve replace replace Remote wall switch is grounding check for ground short repair gr...

Page 19: ...19 W415 0379 B 08 03 05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Page 20: ...20 W415 0379 B 08 03 05 NOTES...