background image

1

Majestic •  MARQ42STIN Installation Manual  •  2272-980 Rev. H  •  4/21 

Installation Manual

Installation and Appliance Setup

NOTICE: DO NOT

 discard this manual!

• 

DO NOT

 store or use gasoline or other flam

-

mable vapors and liquids in the vicinity of this 

or any other appliance.

•  What to do if you smell gas   

DO NOT

 try to light any appliance.

DO NOT

 touch any electrical switch. 

DO 

NOT

 use any phone in your building.

-  Leave the building immediately.
-  Immediately  call  your  gas  supplier  from 

a neighbor’s phone. Follow the gas sup

-

plier’s instructions.

-  If you cannot reach your gas supplier, call 

the fire department.

•  Installation and service must be performed 

by a qualified installer, service agency, or the 

gas supplier.

WARNING: 

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 

could result in serious injury, death, or 

property damage. 

This appliance may be installed as an OEM 

installation  in  manufactured  home  (USA 

only) or mobile home and must be installed 

in  accordance  with  the  manufacturer’s 

instructions  and  the 

Manufactured Home 

Construction and Safety Standard,

 

Title 24 

CFR, Part 3280 

in the United States, or the 

Standard for Installation in Mobile Homes, 

CAN/CSA Z240 MH Series,

 in Canada.

This appliance is only for use with the type(s) 

of  gas  indicated  on  the  rating  plate.  This 

appliance is not convertible for use with other 

gases, unless a certified kit is used.

DANGER

HOT GLASS 

WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN

 TO TOUCH GLASS.

A  barrier  designed  to  reduce  the  risk  of 

burns from the hot viewing glass is provided 

with this appliance and must be installed for 

the  protection  of  children  and  other  at-risk 

individuals.

Models: MARQ42STIN

MARQUIS

SERIES

CAUTION!  Risk of Fire!  DO NOT

 store instruction manuals inside fireplace cavity.                            

High temperatures could cause a fire.                                     

INSTALLER:  Leave this manual with the appliance, not inside the appliance. 

CONSUMER:  Retain this manual for future reference.  Do not store inside the appliance.

Summary of Contents for MARQUIS Series

Page 1: ...tion in manufactured home USA only or mobile home and must be installed in accordance with the manufacturer s instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part...

Page 2: ...al Clearances 15 C Approved Pipe 16 D Use of Elbows 16 E Measuring Standards 17 F Vent Diagrams 18 5 Vent Clearances and Framing A Pipe Clearances to Combustibles 23 B Wall Penetration Framing Firesto...

Page 3: ...ed Exterior wall Roof flashing is installed and sealed ___________________ Verified termination cap is installed and sealed ___________________ Electrical Section 8 Pg 32 33 Verified unswitched power...

Page 4: ...th wood compressed pa per plant fibers plastics or other material that can ignite and burn whether flame proofed or not or plastered or unplastered shall be considered combustible materials G Electric...

Page 5: ...u eled heating appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or local gas i...

Page 6: ...al Pliers Hammer Phillips screwdriver Manometer Gloves Framing square Voltmeter Electric drill and bits 1 4 in Plumb line Safety glasses Level Reciprocating saw Flat blade screwdriver Non corrosive le...

Page 7: ...Follow these instructions carefully during the installation to ensure maximum safety and benefit WARNING Risk of Fire or Explosion Damaged parts could impair safe operation DO NOT install damaged in...

Page 8: ...ure 3 1 Appliance Dimensions Location Inches Millimeters K 15 381 L 12 3 4 324 M 8 dia 203 N 30 762 O 30 3 8 772 P 14 356 Q 6 dia 152 R 22 7 8 875 S 8 203 Location Inches Millimeters A 58 1 8 1476 B 4...

Page 9: ...5 16 IN 1065 mm 37 IN 940 mm 31 1 4 IN 794 mm 1 1 8 IN 29 mm Note See Section 10 for hearth mantel and finishing detail IMPORTANT This fireplace requires an installed decorative barrier front to preve...

Page 10: ...e appliance should be lo cated out of traffic and away from furniture and draperies NOTICE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not d...

Page 11: ...wood WARNING Risk of Fire Maintain specified air space clearances to appliance and vent pipe Insulation and other materials must be secured to prevent accidental contact The chase must be properly bl...

Page 12: ...protected by a noncombustible hearth extension unless the fire place is raised a minimum of three inches above the com bustible floor or hearth See Figures 3 5 3 6 and 3 8 Figure 3 7 Non Combustible Z...

Page 13: ...should also be considered when determining installation dimensions MODEL DESCRIPTION PART ELEVATED APPLIANCE DIMENSION See Note 1 MARQ42STIN Avalon Cast Mantel AFANTC5244 1 2 in Biltmore Cast Mantel A...

Page 14: ...OPENING 4 4 Termination Location and Vent Information Fire Risk Maintain vent clearance to combustibles as specified DO NOT pack air space with insulation or other materials Failure to keep insulatio...

Page 15: ...to non mechanical air supply inlet to building or the combustion air inlet to any other appliance termination mechanical or non mechanical 12 in 305 mm 12 in 305 mm I Clearance to a mechanical powered...

Page 16: ...elbow to the appliance DO NOT attach elbow directly to the appliance Diagonal runs have both vertical and horizontal vent as pects when calculating the effects Use the rise for the vertical aspect an...

Page 17: ...g the following standards Pipe measurements are shown using the effective length of pipe See Section 12 A Figure 12 1 for information on effective length of pipe components Horizontal terminations are...

Page 18: ...the system Any 90 elbow may be replaced with two back to back 45 elbows When penetrating a combustible wall a wall shield firestop must be installed When penetrating a combustible ceiling a ceiling fi...

Page 19: ...4 3 m 10 ft 3 0 m 20 ft 6 1 m 20 ft 6 1 m 40 ft 12 2 m After V1 6 ft then H1 2 x V ft Maximum V1 H1 60 ft Maximum when used with approved termination caps V1 Minimum H1 H2 3 ft 914 mm 18 in 457 mm 4...

Page 20: ...2 X V2 5 ft 1 5 m 9 ft 2 7 m H2 Max 2 X V2 6 ft 1 8 m 12 ft 3 7 m H2 Max 2 X V2 7 ft 2 1 m 14 ft 4 3 m H2 Max 2 X V2 10 ft 3 0 m 20 ft 6 1 m H2 Max 2 X V2 V1 H1 must be adhered to V2 has no specific...

Page 21: ...cific restrictions on this value EXCEPT V1 V2 H1 cannot exceed 60 ft 18 3 m After V1 6 ft then H1 Max V1 x 2 FLUE RESTRICTOR NOTE Flue Restrictor ships in manual bag assembly Note Flue restrictor is p...

Page 22: ...4 ft 1 2 m 5 ft 1 5 m 8 ft 2 4 m 6 ft 1 8 m 12 ft 3 7 m 7 ft 2 1 m 14 ft 4 3 m 10 ft 3 0 m 20 ft 6 1 m H1 and H2 has no specific restrictions EXCEPT after V1 6 ft then Ht Max 2 x V1 VT HT 60 ft Max No...

Page 23: ...one 1 in 25 4 mm above the center of the horizontal vent pipe A DO NOT PACK WITH INSULATION OR OTHER MATERIAL Note Heat shields MUST overlap by a minimum of 1 1 2 in 38 mm DVP heat shield designed to...

Page 24: ...revent overheating Figure 5 3 Installing Ceiling Firestop Figure 5 4 Installing the Attic Shield INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP INSTALLED...

Page 25: ...phase begins Figure 6 2 Seal Cap 3 Remove the two non combustible assemblies by re moving the two 1 4 in screws fastening the non com bustible assemblies to the appliance See Figure 6 3 SHIPPING BRAC...

Page 26: ...air space clearance may cause overheating and fire The diagram shows how to properly position and secure the appliance See Figure 6 5 Nailing tabs are provided to secure the appliance to the framing...

Page 27: ...an 1 2 in 13 mm If predrilling screw holes DO NOT penetrate inner pipe All outer pipe joints must be sealed using one of the meth ods below including the slip section that connects directly to the hor...

Page 28: ...ue is not required All unit collar pipe slip section elbow and cap outer flues shall be sealed B Assemble Slip Sections Slide the inner flue of the slip section into the inner flue of the pipe section...

Page 29: ...ery 8 ft 2 44 m after the maximum allowed 25 ft 7 62 m of unsupported rise Vertical runs originating off the rear of the appliance or after any elbow must be supported every 8 ft 2 44 m Horizontal run...

Page 30: ...pitched roofs Section 4 Figure 4 1 to determine the length of pipe to extend through the roof Slide the roof flashing over the pipe sections extending through the roof as shown in Figure 7 11 Use an e...

Page 31: ...Figure 7 14 Heat shields must overlap 1 1 2 in 38 mm mini mum There are two sections of the heat shield One section is factory attached to the wall shield firestop The other section is factory attache...

Page 32: ...ailure to maintain overlap may cause overheating and fire Vent termination must not be recessed in the wall Siding may be brought to the edge of the cap base Flash and seal as appropriate for siding m...

Page 33: ...the same wall box Accessories Requirements This appliance may be used with a wall switch wall mounted thermostat and or a remote control Wiring for optional Hearth Home Technologies approved accessori...

Page 34: ...liance WARNING Risk of Shock or Explosion DO NOT wire IFT controlled appliance junction box to a switched circuit Incorrect wiring will override IFT safety lockout Refer to Figure 8 3 or 8 4 IFT Wirin...

Page 35: ...m of valve if line pressure is greater than 1 2 psig Gas Pressure Natural Gas Propane Minimum inlet pressure 5 0 in w c 11 0 in w c Maximum inlet pressure 10 0 in w c 13 0 in w c Manifold pressure 3 5...

Page 36: ...pen shutter setting The measurement is taken from the face of the appliance to the end of the silicone cap See Figure 9 1 Push the air handle in to close the air shutter Pull the air handle out to ope...

Page 37: ...a 300 F minimum sealant Refer to Figure 10 1 WARNING Risk of Fire DO NOT apply combustible materials beyond the minimum clearances Comply with all minimum clearances to combustibles as specified in t...

Page 38: ...NING COMBUSTIBLE WALL OR MANTEL LEG FIREPLACE OPENING 7 IN 6 IN MIN FROM OPENING 6 IN MAX COMBUSTIBLE MATERIAL Figure 10 4 Clearances to Combustible Mantel Legs or Wall Projections Figure 10 5 Clearan...

Page 39: ...hich shows the decorative barrier front models and the finishing ma terial thickness allowed Figure 10 7 Approved Decorative Fronts for MARQ42STIN Figure 10 6 Note Optional firescreen sits out 1 1 2 i...

Page 40: ...op of the glass frame toward the fireplace Center the glass between the left and right firebox supports Push up and in and set the glass assembly on the bottom three glass latch tabs See Figure 11 2 F...

Page 41: ...by reversing these glass in stallation instructions REFRACTORY TAB GLASS FRAME TAB Figure 11 7 Top Glass Latch Detail B Remove the Shipping Materials Remove shipping materials from inside or undernea...

Page 42: ...he Heat Zone Gas Kit instructions for the remaining installations steps HEAT ZONE KNOCKOUTS Figure 11 8 Heat Zone Gas Knockouts F Install Light Bulbs Note Light bulbs are shipped in the installation m...

Page 43: ...d install with two screws to firebox bottom 4 Reinstall the two bottom sheet metal refractory stand offs with one screw each See Figure 11 13 SHEET METAL SHEET METAL REFRACTORY STANDOFF REFRACTORY STA...

Page 44: ...d should be enough for 3 to 5 applications Figure 11 17 Ember Placement on Base Refractory I Ember Mineral Wool Placement WARNING Risk of Explosion DO NOT place embers directly over burner ports Impro...

Page 45: ...2 2272 702 22 Log 3 2272 703 23 Log 4 2272 704 24 Log 5 2272 705 25 Log 6 2272 706 26 Log 7 2272 707 27 Log 8 2272 707 27 Log 9 2272 708 28 Log 10 2272 708 28 Log 11 2272 709 29 CAUTION Logs are frag...

Page 46: ...pose of placing logs according to this instruction begin with the pilot on the left side From this position the close side of the unit will be considered the front and the far side of the unit will be...

Page 47: ...0 Twist the log until the notch on the side of the log contacts the second grate tine from the left as shown in Figure 11 The end of the log should rest on a ridge on the burner as shown in Figure 10...

Page 48: ...in toward the burner Figure 16 Log 7 from rear Figure 17 Log 8 from front LOG NUMBER 8 SRV2272 707 Note that Logs 7 and 8 are identical to each other Place Log 8 on top of Log 4 resting on the far lef...

Page 49: ...d third grate tines from the right as shown in Figure 19 The log must NOT block or sit directly over burner ports Figure 19 Log 10 from front Figure 20 Log 11 from front LOG NUMBER 11 SRV2272 709 Plac...

Page 50: ...uipped with an IntelliFire Touch remote control The remote was paired to the fire place and tested at the factory It does not need to be paired again unless an accessory kit will be added at the time...

Page 51: ...m 5 in 127 mm 12 in 305 mm UP DVP HVS Vent Support 12 in 305 mm 14 in 356 mm 1 in 25 mm 8 in 203 mm 6 in 152 mm DVP WS Wall Shield Firestop Finished Height 19 3 4 in 502 mm UNIV AS2 Attic Insulation S...

Page 52: ...heat shield is designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall thickness is less than 4 in 102 mm the existing heat shields must be field trimmed If wall thickness is gre...

Page 53: ...Roof Flashing Cap Shield DRC RADIUS 13 7 8 in 352 mm 9 1 2 in 241 mm 14 in 356 mm COOL ADDM Cap Shield 11 5 8 in 295 mm 5 3 4 in 146 mm 7 1 8 in 181 mm 12 1 8 in 308 mm DVP BEK2 DVP HPC Cap Brick Exte...

Page 54: ...305 mm 1 1 2 in 38 mm 7 3 8 in 187 mm 14 in 356 mm 17 3 4 in 451 mm 7 1 4 in 12 in 305 mm 184 mm 5 1 4 in 133 mm 12 1 2 in 318 mm DVP TVHW VerticalTermination Cap Highwind 14 in 356 mm 12 in 305 mm 16...

Page 55: ...RIPTION PART NUMBER 10 FT PV Wire Harness PVI WH10 20 FT PV Wire Harness PVI WH20 40 FT PV Wire Harness PVI WH40 60 FT PV Wire Harness PVI WH60 80 FT PV Wire Harness PVI WH80 100 FT PV Wire Harness PV...

Page 56: ...1 4 IN 135 mm 2 1 4 IN 57 mm 9 1 2 IN 241 mm 4 3 4 IN 121 mm 2 1 4 IN 57 mm 1 1 2 IN 38 mm 6 1 4 IN 159 mm Front View Top View Side View PVLP BEK Brick Kit PVLP SLP Power Vent Low Profile Note Wire h...

Page 57: ...Keep remote controls out of reach of children See your dealer if you have questions Optional Heat Zone Gas Kit Follow the instruction supplied with the kit for operation See your dealer if you have q...