Do not install on water that is microbiologically unsafe without adequate disinfection before or after the unit. For 
effective disinfection install a Rainfresh Drinking Water System or Rainfresh UV disinfection system.

 

-

 

For use on cold water only. 

 

-

 

Only use thread seal tape 

(Teflon® tape)

 

for fitting connections into unit. 

DO NOT USE pipe dope or chemical 

sealants. 

 

-

 

If water pipes are used to ground electrical system, install jumper wire

 

(#4 gauge solid copper wire) across the unit 

to maintain proper grounding of your electrical system 

-

 

Protect your unit from freezing 

- drain the unit if freezing temperatures exist.

 

-

 

NOTE: IF SOLDER TYPE FITTINGS ARE USED DO NOT USE torch near inlet/outlet connections. 

All solder joints 

should be made before joining pipe to filter head. Use only lead-free solder and flux. 

-

 

DO NOT over-tighten 

metal fittings on to unit connections.  

-

 

You will need softener salt with this unit (not included). Softener salt is sold at most retailers. 

-

 

Place the unit on a flat level surface. Do not place shims under the unit to level it. The weight of the unit full of 
water and salt can cause the softener tank to crack at the shim. 

-

 

The unit should only be moved by 2 or more people due to heavy weight. Failure to do so can result in back or other 
injury. 

-

 

The unit must be installed in an area where there is reasonable access to the salt tank for regular salt filling. 

 
INSTALLATION 

Electrical Requirements: 

 

The automatic control valve requires a constant power supply - 110V AC. We recommend a GFI (ground fault 
interrupter) outlet within 5 feet of the softener. Extension cords are not recommended.  

 

If water pipes are used to ground electrical system, you will need to install a jumper wire across the filter unit. 

 

Unpacking the unit 

The unit includes:  
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Unpack the unit and place it at the location where you intend to install it. 

 

Stand back and look at the softener to make sure it is standing straight up and not 
tilted to one side. Make sure your chosen location will be fairly level, dry, and 
protected from possible freezing conditions. The softener can sit directly on the floor 
and will not corrode. DO NOT set the softener onto make shift platforms as this can 
damage the salt tank, or may cause it to topple.  

 

The system has 3 connections - an inlet, an outlet, and a drain line connection. If you 
are looking at the back of the unit (

fig 1

), the inlet is on the left side. 

Warning: 

Make 

sure that you have correctly identified the inlet of the system. REVERSING THE 

WATER 

IN 

WATER 

OUT 

1)

 

Softener tank 
with control 
valve and bypass 
valve & brine 
(salt)  tank 

 

2)

 

Inlet/outlet elbow fittings (2) 
– ¾” Male NPT 

 

3)

 

Allen key (for ease of opening 
& closing bypass valve) 

 

5)

 

Drain hose (15 ft) with hose 
clamp 

 

4)

 

Brine overflow fitting 

 

6)

 

AC power adapter 

 

Fig 1 

Summary of Contents for 30TFM

Page 1: ...olved over the phone Help Line 1 800 667 8072 Monday to Friday 8 30 AM to 5 00 PM EST www rainfresh ca TABLE OF CONTENTS System Specifications 2 How Your Water Conditioner Works 2 Safety Precautions 2...

Page 2: ...and recharges the resin with sodium As iron is hard to detach from the resin the unit includes an automatic resin cleaner feeder that installs on the salt tank and slowly releases resin cleaner into t...

Page 3: ...e unit must be installed in an area where there is reasonable access to the salt tank for regular salt filling INSTALLATION Electrical Requirements The automatic control valve requires a constant powe...

Page 4: ...sed for irrigation or sprinkler systems You will have to plan the job so that you cut in to feed the softener AFTER these spigots BEFORE YOU BEGIN INSTALLATION CONFIRM THE INLET AND OUTLET OF THE UNIT...

Page 5: ...to a nearby laundry tub standing pipe or floor drain fig 5 and cut off excess tubing NOTE ABOUT DRAIN LINE You can run the drain hose from the unit to the ceiling joists max 8 ft ceiling and run it to...

Page 6: ...et slightly to allow water to run into the unit The water should initially fill the tank slowly Once the tank is full of water you can open valve fully This prevents resin from being pushed up into th...

Page 7: ...ll be accepted and minute value will start flashing MENU BUTTON The function of this key is to enter the level one programming mode where the valve settings can be adjusted SET REGEN BUTTON This butto...

Page 8: ...to accept Flashing stops hour value is highlighted again PROCEED TO STEP 2 CURRENT TIME CURRENT TIME CURRENT TIME CURRENT TIME 07 07 07 07 45 AM 45 AM 45 AM 45 AM 12 Press to advance to CURRENT DATE T...

Page 9: ...again to accept the value Highlight stops flashing CURRENT DAT CURRENT DAT CURRENT DAT CURRENT DATE E E E AUG AUG AUG AUG 15 15 15 15 201 201 201 2015 5 5 5 18 Now press or key to change the value to...

Page 10: ...n malfunction of the unit When the Level 2 Master Programming Mode is entered all available option setting displays may be viewed and set as needed Depending on current option settings some parameters...

Page 11: ...unit set resin volume at 1 0 cu ft For 45TFM unit set resin volume at 1 5 cu ft For 60FM unit set resin volume at 2 0 cu ft 7 Salt Setting Leave at default setting For best results set between 12 lbs...

Page 12: ...mmed settings are stored in a non volatile memory and will not be lost during a power failure If power fails while the unit is in regeneration the valve will finish regeneration after power is restore...

Page 13: ...ly regenerate the softener This should always be followed up by allowing the unit to use up any remaining salt and then thoroughly cleaning out the brine tank If you are unable to break the bridge thi...

Page 14: ...sin in drain line 1 Air in water system 2 Incorrect or missing drain line flow control DLFC 1 Check well system for proper air elimination 2 Check and replace DLFC F Too much water in brine tank 1 Plu...

Page 15: ...3 Hexagon with washer 2 A19 21709003 Secure clip 2 A20 05056140 Valve connector 1 A21 05056065 O ring 23 6x2 65 2 A22 21319006 Screw adaptor 2 A23 05056508 Screw M5x12 Hexagon with washer 5 A24 050300...

Page 16: ...the water quality requirements of the softener This limited Warranty applies only to a unit when returned to the Warrantor at the owner s expense and in accordance with shipping instructions received...

Reviews: