background image

 

 

15

PARTS LIST 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Item 

No. 

Part No. 

Description 

Qty 

A01 

05056087 

Screw - M5x12 

(Hexagon) 

A02 

05056088 

Screw - M5x16 

(Hexagon with 

washer) 

A03 

05056047 

End plug retainer 

A04 

05030002 

Piston rod 

A05 

05056097 

Piston pin 

A06 

05056023 

End plug 

A07 

05056070 

Quad ring 

A08 

05056024 

End plug washer 

A09 

05056022 

Piston retainer 

A10 

05056181 

Piston (electrical) 

A11 

05056104 

Muffler 

A12 

05056021 

Spacer 

A13 

05056073 

Seal 

A14 

05030001 

Valve body 

A15 

05056129 

O-ring φ 23x3 

A16 

05056025 

Adaper coupling 

A17 

05056044 

Adaptor clip 

A18 

05056090 

Screw-ST4. 2x13 

(Hexagon with 

washer) 

A19 

21709003 

Secure clip 

A20 

05056140 

Valve connector 

A21 

05056065 

O-ring φ 23.6x2.65 

A22 

21319006 

Screw adaptor 

A23 

05056508 

Screw M5x12 

(Hexagon with 

washer) 

A24 

05030004 

End cover 

A25 

05030013 

O-ring φ 30x2.65 

A26 

13000426 

Screw-ST2. 9x13 

(Large) 

A27 

07060007 

Valve bottom 

connector 

A28 

26010103 

O-ring φ 25x3.55 

A29 

05056063 

O-ring φ 

78.74x5.33 

 

A30 

05056086 

Screw - M5x30 

(Hexagon with 

washer) 

A31 

05056029 

Injector cover 

A32 

05056072 

O-ring φ 24x2 

A33 

05056027 

Injector nozzle 

 

 

 

 

A34 

05056103 

Injector screen 

A35 

05056028 

Injector throat 

A36 

05056035 

BLFC button 

retainer 

A37 

05056191 

BLFC - 2# 

A38 

05056138 

O-ring φ 14x1.8 

A39 

05056100B 

BLFC fitting 

A40 

05056106 

Brine line screen 

A41 

05056107 

BLFC tube insert 

 

Summary of Contents for 30TFM

Page 1: ...olved over the phone Help Line 1 800 667 8072 Monday to Friday 8 30 AM to 5 00 PM EST www rainfresh ca TABLE OF CONTENTS System Specifications 2 How Your Water Conditioner Works 2 Safety Precautions 2...

Page 2: ...and recharges the resin with sodium As iron is hard to detach from the resin the unit includes an automatic resin cleaner feeder that installs on the salt tank and slowly releases resin cleaner into t...

Page 3: ...e unit must be installed in an area where there is reasonable access to the salt tank for regular salt filling INSTALLATION Electrical Requirements The automatic control valve requires a constant powe...

Page 4: ...sed for irrigation or sprinkler systems You will have to plan the job so that you cut in to feed the softener AFTER these spigots BEFORE YOU BEGIN INSTALLATION CONFIRM THE INLET AND OUTLET OF THE UNIT...

Page 5: ...to a nearby laundry tub standing pipe or floor drain fig 5 and cut off excess tubing NOTE ABOUT DRAIN LINE You can run the drain hose from the unit to the ceiling joists max 8 ft ceiling and run it to...

Page 6: ...et slightly to allow water to run into the unit The water should initially fill the tank slowly Once the tank is full of water you can open valve fully This prevents resin from being pushed up into th...

Page 7: ...ll be accepted and minute value will start flashing MENU BUTTON The function of this key is to enter the level one programming mode where the valve settings can be adjusted SET REGEN BUTTON This butto...

Page 8: ...to accept Flashing stops hour value is highlighted again PROCEED TO STEP 2 CURRENT TIME CURRENT TIME CURRENT TIME CURRENT TIME 07 07 07 07 45 AM 45 AM 45 AM 45 AM 12 Press to advance to CURRENT DATE T...

Page 9: ...again to accept the value Highlight stops flashing CURRENT DAT CURRENT DAT CURRENT DAT CURRENT DATE E E E AUG AUG AUG AUG 15 15 15 15 201 201 201 2015 5 5 5 18 Now press or key to change the value to...

Page 10: ...n malfunction of the unit When the Level 2 Master Programming Mode is entered all available option setting displays may be viewed and set as needed Depending on current option settings some parameters...

Page 11: ...unit set resin volume at 1 0 cu ft For 45TFM unit set resin volume at 1 5 cu ft For 60FM unit set resin volume at 2 0 cu ft 7 Salt Setting Leave at default setting For best results set between 12 lbs...

Page 12: ...mmed settings are stored in a non volatile memory and will not be lost during a power failure If power fails while the unit is in regeneration the valve will finish regeneration after power is restore...

Page 13: ...ly regenerate the softener This should always be followed up by allowing the unit to use up any remaining salt and then thoroughly cleaning out the brine tank If you are unable to break the bridge thi...

Page 14: ...sin in drain line 1 Air in water system 2 Incorrect or missing drain line flow control DLFC 1 Check well system for proper air elimination 2 Check and replace DLFC F Too much water in brine tank 1 Plu...

Page 15: ...3 Hexagon with washer 2 A19 21709003 Secure clip 2 A20 05056140 Valve connector 1 A21 05056065 O ring 23 6x2 65 2 A22 21319006 Screw adaptor 2 A23 05056508 Screw M5x12 Hexagon with washer 5 A24 050300...

Page 16: ...the water quality requirements of the softener This limited Warranty applies only to a unit when returned to the Warrantor at the owner s expense and in accordance with shipping instructions received...

Reviews: