background image

 

 

12

 

  

Salt Setting (lbs/cu ft) 

Model 

6.0 

8.0 

10.0 

12.0 

15.0 

30TFM 

2.9 

3.8 

4.8 

5.7 

7.1 

45TFM 

4.2 

5.7 

7.1 

8.5 

10.7 

60TFM 

5.7 

7.6 

9.6 

11.4 

14.2 

 

Table 1 : Refill time (in minutes) for various salt settings using Sodium Chloride 

 
Disinfecting the Softener 

It  is  possible  that  during  shipping,  storage  &  installing,  bacteria  can  go  into  the  unit. 
Therefore, as a good installation practice, it is recommended that the softener be disinfected 
prior  to  use.  To  disinfect,  open  the  lid  of  the  brine  well  in  the  salt  tank  and  add  approx.  3 
tablespoons of fresh common household bleach. Replace lid & proceed to next step. 

 
Manual Regeneration 

If screen is locked, press “

 MENU” for 3 seconds to unlock. 

 To initiate an immediate regeneration, press the 

SET/REGEN

 

button for 3 seconds, an option for “

Delayed

” or “

Immediate

” regeneration will appear. Press the 

SET/REGEN

 button 

again  and  “

Delayed

”  will  begin  flashing.  Now  press  the  down  arrow  button  and  “

Immediate

”  will  flash.  Press  the 

SET/REGEN

 button once and then press the menu button once. Valve will immediately start manual regeneration.  

YOUR UNIT IS NOW READY FOR SERVICE 

 
 
OTHER FEATURES 

Control Operation During a Power Failure  

In the event of a power failure, the valve will keep track of the time and day for 48 hours.  The programmed settings 
are  stored  in  a  non-volatile  memory  and  will  not  be  lost  during  a  power  failure.    If  power  fails  while  the  unit  is  in 
regeneration, the valve will finish regeneration after power is restored.  If the valve misses a scheduled regeneration 
due to a power failure, it will queue regeneration at the next regeneration time once power is restored. 
 

Safety Float 

The  brine  tank  is  equipped  with  a  safety  float  which  prevents  your  brine  tank  from  overfilling  as  a  result  of  a 
malfunction such as a power failure. 

 

New Sounds 

You  may  notice  new  sounds  as  your  water  softener  operates.  The  regeneration  cycle  lasts  approximately  2  hours. 
During this time, you may hear water running intermittently to the drain. 

 

Manual Bypass 

In  the  case  of  emergency,  such  as  an  overflowing  brine  tank,  you  can  isolate  your  water  softener  from  the  water 
supply using the bypass valve located at the back of the control. To resume soft water service, open bypass valve by 
rotating the knobs counterclockwise. 

 

12  Backwash 

05 

 

 

 

Increase to 10 if water has lot of dirt 
or rust 

13  Brine / Rinse 

50 

 

 

 

Increase to 60 if water is more than 
15 grains hard 

14  Rapid Rinse 

 

 

 

Increase to 10  if you want a longer 
rinse time after regeneration 

15  Refill 

For REFILL settings based on your chosen salt settings, please refer to 

Table 1 

below 

16  Restore Default 

NO 

 

 

 

Leave at default. Change only if you 
would like to re-start programming 
from the beginning 

Open this lid & 
pour bleach inside 

Summary of Contents for 30TFM

Page 1: ...olved over the phone Help Line 1 800 667 8072 Monday to Friday 8 30 AM to 5 00 PM EST www rainfresh ca TABLE OF CONTENTS System Specifications 2 How Your Water Conditioner Works 2 Safety Precautions 2...

Page 2: ...and recharges the resin with sodium As iron is hard to detach from the resin the unit includes an automatic resin cleaner feeder that installs on the salt tank and slowly releases resin cleaner into t...

Page 3: ...e unit must be installed in an area where there is reasonable access to the salt tank for regular salt filling INSTALLATION Electrical Requirements The automatic control valve requires a constant powe...

Page 4: ...sed for irrigation or sprinkler systems You will have to plan the job so that you cut in to feed the softener AFTER these spigots BEFORE YOU BEGIN INSTALLATION CONFIRM THE INLET AND OUTLET OF THE UNIT...

Page 5: ...to a nearby laundry tub standing pipe or floor drain fig 5 and cut off excess tubing NOTE ABOUT DRAIN LINE You can run the drain hose from the unit to the ceiling joists max 8 ft ceiling and run it to...

Page 6: ...et slightly to allow water to run into the unit The water should initially fill the tank slowly Once the tank is full of water you can open valve fully This prevents resin from being pushed up into th...

Page 7: ...ll be accepted and minute value will start flashing MENU BUTTON The function of this key is to enter the level one programming mode where the valve settings can be adjusted SET REGEN BUTTON This butto...

Page 8: ...to accept Flashing stops hour value is highlighted again PROCEED TO STEP 2 CURRENT TIME CURRENT TIME CURRENT TIME CURRENT TIME 07 07 07 07 45 AM 45 AM 45 AM 45 AM 12 Press to advance to CURRENT DATE T...

Page 9: ...again to accept the value Highlight stops flashing CURRENT DAT CURRENT DAT CURRENT DAT CURRENT DATE E E E AUG AUG AUG AUG 15 15 15 15 201 201 201 2015 5 5 5 18 Now press or key to change the value to...

Page 10: ...n malfunction of the unit When the Level 2 Master Programming Mode is entered all available option setting displays may be viewed and set as needed Depending on current option settings some parameters...

Page 11: ...unit set resin volume at 1 0 cu ft For 45TFM unit set resin volume at 1 5 cu ft For 60FM unit set resin volume at 2 0 cu ft 7 Salt Setting Leave at default setting For best results set between 12 lbs...

Page 12: ...mmed settings are stored in a non volatile memory and will not be lost during a power failure If power fails while the unit is in regeneration the valve will finish regeneration after power is restore...

Page 13: ...ly regenerate the softener This should always be followed up by allowing the unit to use up any remaining salt and then thoroughly cleaning out the brine tank If you are unable to break the bridge thi...

Page 14: ...sin in drain line 1 Air in water system 2 Incorrect or missing drain line flow control DLFC 1 Check well system for proper air elimination 2 Check and replace DLFC F Too much water in brine tank 1 Plu...

Page 15: ...3 Hexagon with washer 2 A19 21709003 Secure clip 2 A20 05056140 Valve connector 1 A21 05056065 O ring 23 6x2 65 2 A22 21319006 Screw adaptor 2 A23 05056508 Screw M5x12 Hexagon with washer 5 A24 050300...

Page 16: ...the water quality requirements of the softener This limited Warranty applies only to a unit when returned to the Warrantor at the owner s expense and in accordance with shipping instructions received...