background image

1.

 

Date & Time 

2.

 

Capacity (

gal of water that can be used between 

regenerations

3.

 

Volume Remaining (

gal of water left before regeneration 

begins

4.

 

Regeneration Time (

Time of day when regeneration starts

5.

 

Last Regeneration Date (

Last date when system regenerated

)

 

6.

 

Current Flow Rate (GPM) (

flow rate of water being currently 

used

)

 

7.

 

Peak Flow Rate (GPM) (

Max recorded flow rate of the water

)

 

The control valve has a display screen and 4 buttons 

 

 

 

 

 

 

 

 
 
PROGRAMMING YOUR TFM WATER SOFTENER

 

The valve has 2 levels of programming – Level 1 and Level 2 
You will need to only go through Level 1 programming to start up your unit. Level 2 programming is factory set and 
can be changed only if desired.  
In level 1 programming you can set current time, date, number of people in your home and the feed water hardness. 
Level 1 programming is completed in 5 easy steps. 
 

Level 1 PROGRAMMING 

STEP 1 : Set Current Time 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.

 

Press “ ” (MENU) for 3 
seconds to unlock screen.  

 

5.

 

Press “

” (SET/REGEN) 

once and the highlighted 
value flashes. 

6.

 

Now press “

” (UP) or “ ” 

(DOWN)  key  to  change  the 
hour values to current time.   

 

7.

 

Press 

” 

(SET/REGEN) 

again.  Hour  value  will  be 
accepted  and  minute  value 
will start flashing.   

MENU BUTTON

 

” 

The function of this key is to enter the 
level one programming mode where 
the valve settings can be adjusted. 

SET / REGEN BUTTON

 

” 

This button has two functions.  The first is to initiate a manual regeneration by holding the button 
for 3 or more seconds.  The second function is while in programming mode, pressing this key 
allows the user to change the value of each setting. 

UP / DOWN

 

” 

These buttons are used to increase or 
decrease the value of the settings while in 
the programming mode. 

JAN/21/2015

JAN/21/2015

JAN/21/2015

JAN/21/2015    

05:27 PM

05:27 PM

05:27 PM

05:27 PM    

2.

 

The display will read “

Press 

MENU Key for 3 sec to unlock”

3.

 

After 3 seconds, the display will 
beep confirming unlock 

4.

 

Press “ ” (MENU) again and 
the hour value becomes 
highlighted 

PRESS MENU KEY 

PRESS MENU KEY 

PRESS MENU KEY 

PRESS MENU KEY     

3 SEC TO UNLOCK

3 SEC TO UNLOCK

3 SEC TO UNLOCK

3 SEC TO UNLOCK    

  

  

  

  

CURRENT TIME

CURRENT TIME

CURRENT TIME

CURRENT TIME    

   

   

   

   05

05

05

05

    

: 27 PM

: 27 PM

: 27 PM

: 27 PM

    

  

  

  

  CURRENT TIME

CURRENT TIME

CURRENT TIME

CURRENT TIME    

   

   

   

   05

05

05

05

    

: 27 PM

: 27 PM

: 27 PM

: 27 PM

    

  

  

  

  

CURRENT TIME

CURRENT TIME

CURRENT TIME

CURRENT TIME

    

   

   

   

   00007777

    

: 27 PM

: 27 PM

: 27 PM

: 27 PM

    

  

  

  

  CURRENT TIME

CURRENT TIME

CURRENT TIME

CURRENT TIME    

   

   

   

   07 : 

07 : 

07 : 

07 : 

27

27

27

27

    PM

PM

PM

PM    

Summary of Contents for 30TFM

Page 1: ...olved over the phone Help Line 1 800 667 8072 Monday to Friday 8 30 AM to 5 00 PM EST www rainfresh ca TABLE OF CONTENTS System Specifications 2 How Your Water Conditioner Works 2 Safety Precautions 2...

Page 2: ...and recharges the resin with sodium As iron is hard to detach from the resin the unit includes an automatic resin cleaner feeder that installs on the salt tank and slowly releases resin cleaner into t...

Page 3: ...e unit must be installed in an area where there is reasonable access to the salt tank for regular salt filling INSTALLATION Electrical Requirements The automatic control valve requires a constant powe...

Page 4: ...sed for irrigation or sprinkler systems You will have to plan the job so that you cut in to feed the softener AFTER these spigots BEFORE YOU BEGIN INSTALLATION CONFIRM THE INLET AND OUTLET OF THE UNIT...

Page 5: ...to a nearby laundry tub standing pipe or floor drain fig 5 and cut off excess tubing NOTE ABOUT DRAIN LINE You can run the drain hose from the unit to the ceiling joists max 8 ft ceiling and run it to...

Page 6: ...et slightly to allow water to run into the unit The water should initially fill the tank slowly Once the tank is full of water you can open valve fully This prevents resin from being pushed up into th...

Page 7: ...ll be accepted and minute value will start flashing MENU BUTTON The function of this key is to enter the level one programming mode where the valve settings can be adjusted SET REGEN BUTTON This butto...

Page 8: ...to accept Flashing stops hour value is highlighted again PROCEED TO STEP 2 CURRENT TIME CURRENT TIME CURRENT TIME CURRENT TIME 07 07 07 07 45 AM 45 AM 45 AM 45 AM 12 Press to advance to CURRENT DATE T...

Page 9: ...again to accept the value Highlight stops flashing CURRENT DAT CURRENT DAT CURRENT DAT CURRENT DATE E E E AUG AUG AUG AUG 15 15 15 15 201 201 201 2015 5 5 5 18 Now press or key to change the value to...

Page 10: ...n malfunction of the unit When the Level 2 Master Programming Mode is entered all available option setting displays may be viewed and set as needed Depending on current option settings some parameters...

Page 11: ...unit set resin volume at 1 0 cu ft For 45TFM unit set resin volume at 1 5 cu ft For 60FM unit set resin volume at 2 0 cu ft 7 Salt Setting Leave at default setting For best results set between 12 lbs...

Page 12: ...mmed settings are stored in a non volatile memory and will not be lost during a power failure If power fails while the unit is in regeneration the valve will finish regeneration after power is restore...

Page 13: ...ly regenerate the softener This should always be followed up by allowing the unit to use up any remaining salt and then thoroughly cleaning out the brine tank If you are unable to break the bridge thi...

Page 14: ...sin in drain line 1 Air in water system 2 Incorrect or missing drain line flow control DLFC 1 Check well system for proper air elimination 2 Check and replace DLFC F Too much water in brine tank 1 Plu...

Page 15: ...3 Hexagon with washer 2 A19 21709003 Secure clip 2 A20 05056140 Valve connector 1 A21 05056065 O ring 23 6x2 65 2 A22 21319006 Screw adaptor 2 A23 05056508 Screw M5x12 Hexagon with washer 5 A24 050300...

Page 16: ...the water quality requirements of the softener This limited Warranty applies only to a unit when returned to the Warrantor at the owner s expense and in accordance with shipping instructions received...

Reviews: