ESP-SMT Smart Modular Control System
36
Advanced Controller Setup
Allows you to set an ETo adjustment
factor, set a Zone to Zone Delay and/
or Suspend Watering when rainfall
exceeds a user set value, and/or when
the temperature falls below a user-set
value.
F
If you would like to globally program
the controller to:
• Set an ETo adjustment factor to
adjust for sensor placement.
• Set a time delay between one
valve turning off and the next
valve turning on.
• Suspend irrigation when rainfall
exceeds a specific amount.
• Suspend irrigation when the
temperature falls below a preset
level.
Press the
UP and Down
arrow
button(s) until
Adv. Controller
Setup
is blinking on the display;
then press the
SELECT
button.
G
The ADV CONTROLLER SETUP
screen will appear with the
value
for the ET Adjustment factor
blinking;
a.
Press the
- or +
button(s) to set the
desired ET adjustment factor; then
press the
NEXT
button.
!
NOTE:
This feature can be used
to globally increase or decrease
the calculated ETo value thereby
adjusting the overall water needs.
b.
Press the
- or +
button(s) to set the
desired zone delay time value; then
press the
NEXT
button.
!
NOTE:
An ideal application of the
Zone to Zone Delay feature is for a
slow filling well in which a delay
is required to allow the well to fill
back to a minimum level prior to
the next zone irrigating.
c.
The Suspend Watering When Rain
Over
value
will begin to blink.
Press the
- or +
button(s) to set the
desired rainfall value; then press the
NEXT
button.
!
NOTE:
The Suspend Watering
When Rain Over XX inches feature
allows you to customize how
much rainfall is required before
suspension of the irrigation
system will occur.
F
c.
G
b.
G
a.
G
SPECIAL FEATURES
Event Days Off
Adv. Controller Setup
Advanced Zone Setup
SELECT
Save Contractor Dflts
Set Units
Short Circuit Test
ADV CONTROLLER SETUP
ETo Adjust Factor
Zone To Zone Delay
Suspend Watering When
Rain Reaches
-OR- Temp Below
100%
2 Seconds
0.04in
35°F
NEXT
BACK
ADV CONTROLLER SETUP
ETo Adjust Factor
Zone To Zone Delay
Suspend Watering When
Rain Reaches
-OR- Temp Below
90%
2
Seconds
0.04in
35°F
NEXT
BACK
ADV CONTROLLER SETUP
ETo Adjust Factor
Zone To Zone Delay
Suspend Watering When
Rain Reaches
-OR- Temp Below
90%
4 Seconds
0.04
in
35°F
NEXT
BACK