The CYCLE/SOAK screen will appear
with 0° - 2° blinking.
a.
Use the
up or down
arrow
button(s) to select the slope degree
category representative of the
zone topography. Press the
NEXT
button.
b.
The Automatic Cycle and Soak
Mode will blink. If you agree with the
automatically calculated maximum
cycle value and the minimum soak
value, press the
NEXT
button.
c.
If you want to change the
automatically calculated cycle and
soak values, press either the
- or +
button(s) and Custom will blink.
Press the
NEXT
button.
d.
The Maximum Cycle value will blink.
Use
- or +
button(s) the to increase
or decrease the maximum cycle
time. Press the
NEXT
button.
e.
The Minimum Soak value will blink.
Use the
- or +
button(s) to change
to the desired minimum soak time
value.
f.
Press the
NEXT
button. The Plant
Type screen will appear.
S
CYCLE/SOAK
Select Slope in Deg.
0-2°
3-4°
5-7°
8°-up
Cycle/Soak
Automatic
Max Cycle
Min
Min Soak
(6)
(40)
Min
Zone xx
NEXT
BACK
S
CYCLE/SOAK
Slope in Deg.
8°-up
Custom
Cycle/Soak Mode
Max Cycle
Min
Min Soak
(4)
(32)
(4)
(32) Min
Zone xx
NEXT
BACK
S
CYCLE/SOAK
Slope in deg.
Cycle/Soak Mode
8°-up
Automatic
Custom
Max Cycle
Min
Min Soak
(4)
(32)
(4)
(32) Min
Zone xx
NEXT
BACK
S
CYCLE/SOAK
Select Slope in Deg.
0-2°
3-4°
5-7°
8°-up
Cycle/Soak
Automatic
Max Cycle
Min
Min Soak
(6)
(40)
Min
Zone xx
NEXT
BACK
S
CYCLE/SOAK
Slope in deg.
Cycle/Soak Mode
8°-up
Automatic
Custom
Max Cycle
Min
Min Soak
(4)
(32)
(8)
(32)
Min
Zone xx
NEXT
BACK
S
CYCLE/SOAK
Slope in Deg.
8°-up
Custom
Cycle/Soak Mode
Max Cycle
Min
Min Soak
(4)
(32)
(8)
(50) Min
Zone xx
NEXT
BACK
b.
a.
e.
f.
d.
c.