7
CT102 Thermostat
Z Wave
®
•
Temperature Filter Upper Bound (8-bit)
The thermostat will report ambient temperature changes for
temperature values greater than the upper bound. This field
must be between 0F and 124F. By default, this value is 0F
(report all temperature changes).
Thermostat Reporting Filter Report Command Definition
7
6
5
4
3
2
1
0
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION_SET
Parameter = 0x0A
Precision (0x00)
Scale
Bound Size (0x01)
Temperature Filter Lower Bound
Temperature Filter Upper Bound
•
Parameter (8-bit)
The parameter is set to 10 (0x0A) for the temperature
reporting filter.
•
Temperature Filter Lower Bound (8-bit)
The thermostat will report ambient temperature changes for
temperature values less than the lower bound. This field must
be between 0F and 124F. By default, this value is 124F (report
all temperature changes).
•
Temperature Filter Upper Bound (8-bit)
The thermostat will report ambient temperature changes for
temperature values greater than the upper bound. This field
must be between 0F and 124F. By default, this value is 0F
(report all temperature changes).
11. Simple UI Mode Enable / Disable
If set to 0, Simple UI mode is disabled. If set to 1, Simple UI mode
is enabled.
12. Multicast Enable/Disable (8-bit)
If set to 0, Multicast is disabled. If set to 1, Multicast is enabled.
Summary of Contents for CT102
Page 3: ...3 Radio Thermostat Getting Started ...
Page 11: ...11 Radio Thermostat Setup ...
Page 17: ...17 Radio Thermostat Wiring Diagrams ...
Page 26: ...Radio Thermostat 3 Product Overview ...
Page 34: ...Radio Thermostat 11 Customization ...
Page 48: ...RTCOA logo sheet 7aug07 CT102 THERMOSTAT Z WAVE REFERENCE ...