5
CT102 Thermostat
Z Wave
®
4. C-Wire/Battery Status (8-bit)
If 0x01, the thermostat is powered by a C-wire. If 0x02, the
thermostat is powered by batteries.
5. Humidity Reporting Threshold (8-bit)
This value determines the reporting threshold when association
reporting is enabled. Unsupported values are ignored.
6. Auxiliary/Emergency (8-bit)
If set to 0, auxiliary / emergency heat is disabled. All other values
(1-255) enable auxiliary / emergency heat. This can only be
enabled when the thermostat is set to Heat Pump mode.
7. Thermostat Swing Temp
The thermostat swing temperature is in units of 0.5 degrees
Fahrenheit. A value of 0x01 is 0.5F and 0x02 is 1.0F. The supported
values may vary from thermostat to thermostat but typically the
allowed values are 0.5F (0x01) to 4.0F (0x08).
8. Thermostat Diff Temp
The thermostat differential temperature is in units of 0.5 degrees
Fahrenheit. A value of 0x04 is 2.0F and 0x06 is 3.0F. The differential
temperature must be an integer value. Non-integer values, such
as 1.5F (0x03), should not be used. The supported values may vary
from thermostat to thermostat but typically, the allowed values are
2.0F (0x04) to 6.0F (0x0C).
9. Thermostat Recovery Mode
The Thermostat Recovery Mode can be either fast (0x01) or
economy (0x02).
Summary of Contents for CT102
Page 3: ...3 Radio Thermostat Getting Started ...
Page 11: ...11 Radio Thermostat Setup ...
Page 17: ...17 Radio Thermostat Wiring Diagrams ...
Page 26: ...Radio Thermostat 3 Product Overview ...
Page 34: ...Radio Thermostat 11 Customization ...
Page 48: ...RTCOA logo sheet 7aug07 CT102 THERMOSTAT Z WAVE REFERENCE ...