background image

11

Replacing the Reactor Cell

In order for the VK 102 and VK 103 to remain functional, the reactor chamber must be replaced every 

8000 hours. Your unit will indicate that a change is required by displaying a “-0001” code on the LED 

Display . 

1.

 From the top PCB board 

, disconnect the 2 

cables connecting the reactor cell to the back 
of the unit 

.

2.

 On the side, you will see 2 long cables con-

necting the reactor cell to the bottom right 
of the unit. One cable Is red and yellow, while 
the other one Is black and white. Disconnect 
these cables and bring them the front of the 
unit.

3.

 Remove the 2 screws on the 

 top and 3 

screws on the bottom, which attach the reac-
tor cell to the unit.

4.

 You can now remove the old reactor cell, 

making sure no wires are still connected to 
the main unit

5.

 You must now separate the top white part 

, holding the PCB board, from the old reac-

tor cell and move It to the new reactor cell. 
First, unscrew the top 4 screws 

, that attach 

the white, metal box to the old reactor cell.

6.

 Unscrew the 2 screws holding the com-

ponent marked with 

, and disconnect the 

wires 

.

7.

 Now carefully lift the top part, holding the 

PCB, and mount it on the new reactor cell in 
reverse order. Then place the new reactor cell 
inside the unit and assemble in reverse order.

8.

 Now switch your VK 102 or VK 103 back on, 

press and hold the down button for 14 sec-
onds, to reset the warning timer. Your VK 102 
or VK 103 is ready for the next 8000 hours.

Summary of Contents for Viruskiller VK 102

Page 1: ...USER GUIDE AND INSTRUCTIONS AIR STERILISER VK 102 VK 103...

Page 2: ......

Page 3: ...T a toy This appliance is NOT to be used by children or persons with reduced physical sensory or mental capabilities Children should be supervised at all times Never look directly at a burning ultra v...

Page 4: ...10 REPLACING THE HEPA FILTER 10 REPLACING THE REACTOR CHAMBER 11 ERROR MESSAGES 12 TROUBLESHOOTING 13 CUSTOMER SERVICES 14 SPECIFICATIONS 14 Warning Indicates important safety instructions that must b...

Page 5: ...use serious injuries Do not sit stand or place heavy objects on the unit as this may result in injury and or damage to the unit Do not block the air inlet of the unit as this will reduce the airflow a...

Page 6: ...icted or obstructed by large items such as furni ture electronic items or cur tains Use a dedicated power outlet Lightning or static electricity could affect the circuit and may cause a fire or damage...

Page 7: ...splay and monitoring Reactor Cell Sirocco Fan Carbon Filter HEPA Filter Pre Filter Four Way Air Inlet Back filter tray Lower filter tray THE UNIT The VK 103 has an extra back filter tray which allows...

Page 8: ...from blue to red it is time to replace the filters VOC s Static Display Color indicates air quality blue good yellow normal red poor Dust Static Display Color indicates air quality blue good yellow no...

Page 9: ...an speed Fan speeds FAN 1 Quiet FAN 2 Normal FAN 3 High Speed Decrease fan speed 3 Mode Changes the information displayed on the LED in the following order UV Lamp Time Current Temp Fan Speed 4 Timer...

Page 10: ...Repeat the process for the top filter case 1 Pull out the bottom filter case 2 Separate the carbon filter and HEPA filter from the pre filter 3 Replace them with new filters 4 Place them back into th...

Page 11: ...s on the bottom which attach the reac tor cell to the unit 4 You can now remove the old reactor cell making sure no wires are still connected to the main unit 5 You must now separate the top white par...

Page 12: ...t working properly Turn the unit off and contact customer service Cleaning the Air Quality Sensor IAQ Sensor Cleaning the Indoor Air Quality IAQ Sensor The IAQ sensor is a very delicate instrument tha...

Page 13: ...not work properly The indoor air is heavily contaminated The room requires ventilation The pre filter is blocked Clean the pre filter The HEPA filter is blocked Replace the HEPA filter The room is to...

Page 14: ...d by unauthorized disassembling or modifications repair or replacement undertaken by unauthorized persons non adherence to the instructions provided in this user guide and as given by the local custom...

Page 15: ......

Page 16: ...BL1 4BA Tel 44 0 1204 238823 E mail info radic8 com Manufacturer INBair Korea LTD 3 4F 72 Jomaru ro 411 Beon gil Bucheon si Gyeonggi do South Korea E mail inbair01 naver com www inbair com Made in Kor...

Reviews: