background image

13

TROUBLESHOOTING

Before you call for service, review this list. It may save you time and expense. This list includes co-
mmon occurrences that are not the result of defect in workmanship or materials.

Problem

Possible cause

Solution

The product 

will not turn on

The plug is not properly insert-

ed in the grounded outlet. 

Plug the device into a working grounded 

outlet.

The remote control is out of 

battery power

Replace the batteries according to the 

polarity.

The voltage of the AC outlet is 

too low

Make sure you plug the unit into its dedi-

cated, grounded 220 AC outlet.

Weak airflow and 

noise from the 

product.

The pre-filter has accumulated 

too much dust.

Clean the pre-filter to avoid this problem 

Also change the HEPA filter when due.

The timer preset 

does not work.

The timer function has not been 

activated.

Set the timer, according to the instruc-

tions in this manual.

The air purifying 

function does not 

work properly.

The indoor air is heavily 

contaminated

The room requires ventilation. 

The pre filter is blocked

Clean the pre filter.

The HEPA filter is blocked

Replace the HEPA filter.

The room is too large for the 

unit

Select the right Viruskiller according to 

the room size.

The airflow is restricted

Make sure there is enough clearance 

around the product and that the air inlet 

and outlet of the unit are unobstructed.

Strange smell is 

emitted from the 

device.

New  product odour

The antimicrobial coating of the reactor 

cell might release a small amount of 

harmless odor. It should disappear in 

one to two weeks.

Moist filters

When cleaning the pre-filter with water, 

make sure it is completely dry before 

reinstalling.

The product has been used in 

environments with a high con-

centration of food odours.

Food odors are oily and can penetrate 

into the filter or the sterilizing module. 

Use proper ventilation.

The product has been used 

in environments with a high 

concentration of smoke.

In areas emitting too much smoke, the 

performance of the sterilizing module 

may be affected. Use proper ventilation.

Summary of Contents for Viruskiller VK 102

Page 1: ...USER GUIDE AND INSTRUCTIONS AIR STERILISER VK 102 VK 103...

Page 2: ......

Page 3: ...T a toy This appliance is NOT to be used by children or persons with reduced physical sensory or mental capabilities Children should be supervised at all times Never look directly at a burning ultra v...

Page 4: ...10 REPLACING THE HEPA FILTER 10 REPLACING THE REACTOR CHAMBER 11 ERROR MESSAGES 12 TROUBLESHOOTING 13 CUSTOMER SERVICES 14 SPECIFICATIONS 14 Warning Indicates important safety instructions that must b...

Page 5: ...use serious injuries Do not sit stand or place heavy objects on the unit as this may result in injury and or damage to the unit Do not block the air inlet of the unit as this will reduce the airflow a...

Page 6: ...icted or obstructed by large items such as furni ture electronic items or cur tains Use a dedicated power outlet Lightning or static electricity could affect the circuit and may cause a fire or damage...

Page 7: ...splay and monitoring Reactor Cell Sirocco Fan Carbon Filter HEPA Filter Pre Filter Four Way Air Inlet Back filter tray Lower filter tray THE UNIT The VK 103 has an extra back filter tray which allows...

Page 8: ...from blue to red it is time to replace the filters VOC s Static Display Color indicates air quality blue good yellow normal red poor Dust Static Display Color indicates air quality blue good yellow no...

Page 9: ...an speed Fan speeds FAN 1 Quiet FAN 2 Normal FAN 3 High Speed Decrease fan speed 3 Mode Changes the information displayed on the LED in the following order UV Lamp Time Current Temp Fan Speed 4 Timer...

Page 10: ...Repeat the process for the top filter case 1 Pull out the bottom filter case 2 Separate the carbon filter and HEPA filter from the pre filter 3 Replace them with new filters 4 Place them back into th...

Page 11: ...s on the bottom which attach the reac tor cell to the unit 4 You can now remove the old reactor cell making sure no wires are still connected to the main unit 5 You must now separate the top white par...

Page 12: ...t working properly Turn the unit off and contact customer service Cleaning the Air Quality Sensor IAQ Sensor Cleaning the Indoor Air Quality IAQ Sensor The IAQ sensor is a very delicate instrument tha...

Page 13: ...not work properly The indoor air is heavily contaminated The room requires ventilation The pre filter is blocked Clean the pre filter The HEPA filter is blocked Replace the HEPA filter The room is to...

Page 14: ...d by unauthorized disassembling or modifications repair or replacement undertaken by unauthorized persons non adherence to the instructions provided in this user guide and as given by the local custom...

Page 15: ......

Page 16: ...BL1 4BA Tel 44 0 1204 238823 E mail info radic8 com Manufacturer INBair Korea LTD 3 4F 72 Jomaru ro 411 Beon gil Bucheon si Gyeonggi do South Korea E mail inbair01 naver com www inbair com Made in Kor...

Reviews: