background image

27 

“OK  will  appear  on  the  display  for  5 
second,  confirming  that  the  Program 
sequence 

has 

been 

carried 

out 

successfully. 
System  is  now  set  to  adjust  the 
temperature  according  to  the  new 
adjustment of program P1. 

 

Note:

  it  is  possible  to  exit  any  time  from 

the 

program 

sequence, 

without 

displaying every hour until Day 7. 
To do so, just hol

d “F” button and press “-

“ button. 

 

 

N.B.: 

You  can  abort  the  display/modification  sequence  anytime,  deleting  any  settings  that  have  not  been  saved,  just  by 
pressing “Stand-By” button; 

Restoring the default settings will delete every P1 Program previously created (see paragraph 6.3); 

If no button is pressed  within  90 sec.  during the Program setting  process, the result  will  be  the cancellation  of  the 
display/modification procedure and will restore back the factory default settings; 

During  the  programmation  process,  the  heating  elements  will  automatically  switch  to  Stand-by  mode,  and  the 
radiator does not heat. 

 

EXAMPLE: HOW TO SET A CUSTOM PROGRAM 
 
Let’s see how to program a brand-new radiator, and anticipate the change from ECO to COMFORT temperature one hour 
earlier (06:00 a.m. is the default factory settings), for each day from Monday to Friday. 
 

Press “M” to select Program P1 

 

 

Set the current day of the week (first use 
of the radiator) using “+” or “-“ button. 

 

 

Press  “M”  and  set  the  current  Hour  (first 
use of the radiator) using “+” or “-“ button. 

 

 

Press  “M”  and  set  the  current  Minutes 
(first  use  of  the  radiator)  using  “+”  or  “-“ 
button. 

 

 

Press  “M”  to  end  the  time  setting 
procedure.  System  now  gets  back  to 
Program P1. 

 

 

 
Hold  “-“  for  3  sec.  To  enter  the 
display/modification of Day 1. 
 

 

 

Summary of Contents for KLIMA Series

Page 1: ...e consultazioni GB Please retain these instructions in a safe place for future reference FR Conserver cette notice pour toute consultation ult rieure RO Pastrati instructiunile pentru consultari ulter...

Page 2: ...2 n 1 n 1 n 4 5x60mm n 4 8x50mm 1 4 mm 2 3 4 min 15cm min 15cm min 15cm min 50cm min 15cm 1 1 3 3 2 2 4 4...

Page 3: ...3 6 8 7 click 5 click A B...

Page 4: ...4 9 3m 1m 4m 3m...

Page 5: ...r mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children...

Page 6: ...wn in figure 4 Rest the bracket on the floor to use it as a template to mark the points a which the two lower fixing holes are to be made figure 5A Lift the bracket until its lower fixing points coinc...

Page 7: ...unction controlled by the key pushed 6 2 2 Switching the radiator on and off The power supply to the radiator is controlled by a two pole electromechanical switch G located on the right side of the ra...

Page 8: ...ode to Comfort mode Icon Description When used Comfort When at home The radiator works to maintain the comfort temperature set Eco When you are away from home for short periods from 2 to 48 hours or y...

Page 9: ...mes by going to Comfort mode first using the M key and then selecting the value required using the and keys Please note In Pilot Wire mode the Eco temperature is always equal to the Comfort temperatur...

Page 10: ...ing saved the date and time this setting procedure will be activated automatically 6 2 6 Customizing P1 Program Program P1 may be modified to suit the users needs Modification of P1 gives the user the...

Page 11: ...ation involves the period of time between 23 00 and 00 00 Having modified the temperature for each of the 23 hours of Day 1 press further button to enter the modification mode of Day 2 Press button to...

Page 12: ...esult will be the cancellation of the display modification procedure and will restore back the factory default settings During the programmation process the heating elements will automatically switch...

Page 13: ...ay directly Day 3 Wednesday Repeat the procedure previously described until D 6 appears on the display Since we don t want to modify Day 6 and 7 we can exit the Program settings mode holding F and pre...

Page 14: ...e by pushing the or keys respectively Activation is indicated by the relevant icon that switches on on the display Daily consumption This function makes it possible to view the power the radiator has...

Page 15: ...aving Thanks to this function which can only be activated in Comfort mode the radiator continuously monitors the room and if no people are detected it reduces the comfort temperature set as follows Pe...

Page 16: ...er being interrupted for more than 30 minutes when it is switched on Stand by mode is not set as normally happens by Comfort mode starts immediately The comfort temperature is as set before the power...

Page 17: ...raughts The temperature in the room differs from the temperature set Having waiter for the ambient temperature to stabilise for at least 4 hours you may have to compensate for any differences between...

Page 18: ...In standby mode elSB 0 00025 kW Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic roo...

Reviews: