To  switch  on  the  radiator,  push  the 
Switch on / Stand-by key. 
 

 

 

 

The radiator always comes on in comfort 
mode.  If the radiator is new or the power 
supply  has  been  off  for  more  than  30 
minutes,  the  comfort  temperature  is  at 
the default value of 19°C. 

To  switch  off  the  radiator,  hold  down  the 
Switch  on  /  Stand-by  key  for  at  least  3 
seconds.  
 

 

 

 

Switching  the  radiator  off  using  the 
rocking  switch  on  its  side  for  more  than 
30  minutes  results  in  the  loss  of  all  data 
saved  (date,  time,  temperature  setting, 
etc.).  

 

6.2.3 Selecting the operating mode 
 

Pressing  the  "M"  key  repeatedly  allows 
you  to  select  the  operating  mode  you 
require.  
 

 

 

 

 

The operating modes are activated in the 
following order:  
 

 

 

→ 

 

→ 

 

→ 

 

→ 

 

→ 

 

 
Once  30"  has  elapsed  since  the  "M"  key 
was  last  pushed,  the  operating  mode 
activation  sequence  begins  from  the 
beginning  again,  to  make  it  quicker  to 
switch from any mode to Comfort mode.  

Icon 

Description 

When used 

 

Comfort 

When at home  The radiator works to maintain the comfort temperature set.  

 

Eco 

When you are away  from home for short periods (from 2 to 48  hours) or  you 
are  sleeping.    The  radiator  works  to  maintain  the  eco  temperature  set  and 
save energy.  

 

Anti-freeze  

When  you  are  away  from  home  for  long  periods  (more  than  48  hours).    The 
temperature is automatically set at 7±3°C and cannot be changed.  

 

Programme P1 

When  you  want  preset  programmed  operation,  suitable  for  those  that  do  not 
work  from  home.  THIS  PROGRAM  CAN  ALSO  BE  CUSTOMIZED 
FOLLOWING THE INSTRUCTIONS LISTED IN PARAGRAPH 6.2.6. 

 

Programme P2 

When  you  want  preset  programmed  operation,  suitable  for  holiday  homes 
used at the weekend.  

 

Programme P3 

When  you  want  preset  programmed  operation,  suitable  for  offices  and 
workplaces.  

 

Pilot wire  

When checking operation of the radiator, using an external control unit with a 
pilot wire.  

 
6.2.3.1 Description of preset programmes 
 

 

            

                              00:00                 06:00 08:00        12:00 14:00    17:00                     24:00 

Monday-Friday   



 

Saturday-Sunday 



 

 

Summary of Contents for KLIMA Series

Page 1: ...e consultazioni GB Please retain these instructions in a safe place for future reference FR Conserver cette notice pour toute consultation ult rieure RO Pastrati instructiunile pentru consultari ulter...

Page 2: ...2 n 1 n 1 n 4 5x60mm n 4 8x50mm 1 4 mm 2 3 4 min 15cm min 15cm min 15cm min 50cm min 15cm 1 1 3 3 2 2 4 4...

Page 3: ...3 6 8 7 click 5 click A B...

Page 4: ...4 9 3m 1m 4m 3m...

Page 5: ...r mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children...

Page 6: ...wn in figure 4 Rest the bracket on the floor to use it as a template to mark the points a which the two lower fixing holes are to be made figure 5A Lift the bracket until its lower fixing points coinc...

Page 7: ...unction controlled by the key pushed 6 2 2 Switching the radiator on and off The power supply to the radiator is controlled by a two pole electromechanical switch G located on the right side of the ra...

Page 8: ...ode to Comfort mode Icon Description When used Comfort When at home The radiator works to maintain the comfort temperature set Eco When you are away from home for short periods from 2 to 48 hours or y...

Page 9: ...mes by going to Comfort mode first using the M key and then selecting the value required using the and keys Please note In Pilot Wire mode the Eco temperature is always equal to the Comfort temperatur...

Page 10: ...ing saved the date and time this setting procedure will be activated automatically 6 2 6 Customizing P1 Program Program P1 may be modified to suit the users needs Modification of P1 gives the user the...

Page 11: ...ation involves the period of time between 23 00 and 00 00 Having modified the temperature for each of the 23 hours of Day 1 press further button to enter the modification mode of Day 2 Press button to...

Page 12: ...esult will be the cancellation of the display modification procedure and will restore back the factory default settings During the programmation process the heating elements will automatically switch...

Page 13: ...ay directly Day 3 Wednesday Repeat the procedure previously described until D 6 appears on the display Since we don t want to modify Day 6 and 7 we can exit the Program settings mode holding F and pre...

Page 14: ...e by pushing the or keys respectively Activation is indicated by the relevant icon that switches on on the display Daily consumption This function makes it possible to view the power the radiator has...

Page 15: ...aving Thanks to this function which can only be activated in Comfort mode the radiator continuously monitors the room and if no people are detected it reduces the comfort temperature set as follows Pe...

Page 16: ...er being interrupted for more than 30 minutes when it is switched on Stand by mode is not set as normally happens by Comfort mode starts immediately The comfort temperature is as set before the power...

Page 17: ...raughts The temperature in the room differs from the temperature set Having waiter for the ambient temperature to stabilise for at least 4 hours you may have to compensate for any differences between...

Page 18: ...In standby mode elSB 0 00025 kW Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic roo...

Reviews: