background image

26 

To display P1 Program hold button “-“ for 
3 seconds. 
 

 

 

 

The  first  day  to  see/modify  is  now 
displayed (1= Monday) 

Press “+” button to enter the first hour to 
see/modify. 
 

 

 

 

Press  “M”  button  to  choose  the  wished 
temperature level among Comfort, Eco or 
Frost Free: 
 

 

 

 

 

→ 

 

 

The  displayed  temperature  once  you’ve 
selected a specific hour of the day, is the 
one currently set on the P1 Program. 

Use  “+”  and  “-“  buttons  to  enter  each 
hour of day 1 and see/modify the working 
temperature of each of them. 
 

 

 

 

The  hour  displayed  always  indicates  the 
starting point. For example: when H 23 is 
displayed  the  modification  involves  the 
period of time between 23:00 and 00:00. 

Having modified the temperature for each 
of the 23 hours of Day 1, press 

further “+” 

button  to  enter  the  modification  mode  of 
Day 2. 
 

 

 

Press  “+”  button  to  diplay/modify  the 
working temperature of each hour of Day 
2, as descrive for Day 1. 
You  can  set  automatically  the  same 
program  of  Day  1  on  Day  2  by  holding 
the “F” button and pressing “+” button. 

 

 

 

Note

: you are allowed to copy and paste 

the  same  daily  program  ONLY  WHEN 
the number of the day you wish to adjust 
is  displayed  (as  showed  in  the  picture), 
BUT NOT when the hour is displayed. 

Once  the  last  day  (Day  7)  has  been  set, 
press  “+”  button  to  end  the  program 
sequence. 
 
  

 

 

 

 
END will appear on the display. A further 
pression  of  “+”  button  will  allow  you  to 
confirm the adjusted program. 
 

Summary of Contents for KLIMA Series

Page 1: ...e consultazioni GB Please retain these instructions in a safe place for future reference FR Conserver cette notice pour toute consultation ult rieure RO Pastrati instructiunile pentru consultari ulter...

Page 2: ...2 n 1 n 1 n 4 5x60mm n 4 8x50mm 1 4 mm 2 3 4 min 15cm min 15cm min 15cm min 50cm min 15cm 1 1 3 3 2 2 4 4...

Page 3: ...3 6 8 7 click 5 click A B...

Page 4: ...4 9 3m 1m 4m 3m...

Page 5: ...r mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children...

Page 6: ...wn in figure 4 Rest the bracket on the floor to use it as a template to mark the points a which the two lower fixing holes are to be made figure 5A Lift the bracket until its lower fixing points coinc...

Page 7: ...unction controlled by the key pushed 6 2 2 Switching the radiator on and off The power supply to the radiator is controlled by a two pole electromechanical switch G located on the right side of the ra...

Page 8: ...ode to Comfort mode Icon Description When used Comfort When at home The radiator works to maintain the comfort temperature set Eco When you are away from home for short periods from 2 to 48 hours or y...

Page 9: ...mes by going to Comfort mode first using the M key and then selecting the value required using the and keys Please note In Pilot Wire mode the Eco temperature is always equal to the Comfort temperatur...

Page 10: ...ing saved the date and time this setting procedure will be activated automatically 6 2 6 Customizing P1 Program Program P1 may be modified to suit the users needs Modification of P1 gives the user the...

Page 11: ...ation involves the period of time between 23 00 and 00 00 Having modified the temperature for each of the 23 hours of Day 1 press further button to enter the modification mode of Day 2 Press button to...

Page 12: ...esult will be the cancellation of the display modification procedure and will restore back the factory default settings During the programmation process the heating elements will automatically switch...

Page 13: ...ay directly Day 3 Wednesday Repeat the procedure previously described until D 6 appears on the display Since we don t want to modify Day 6 and 7 we can exit the Program settings mode holding F and pre...

Page 14: ...e by pushing the or keys respectively Activation is indicated by the relevant icon that switches on on the display Daily consumption This function makes it possible to view the power the radiator has...

Page 15: ...aving Thanks to this function which can only be activated in Comfort mode the radiator continuously monitors the room and if no people are detected it reduces the comfort temperature set as follows Pe...

Page 16: ...er being interrupted for more than 30 minutes when it is switched on Stand by mode is not set as normally happens by Comfort mode starts immediately The comfort temperature is as set before the power...

Page 17: ...raughts The temperature in the room differs from the temperature set Having waiter for the ambient temperature to stabilise for at least 4 hours you may have to compensate for any differences between...

Page 18: ...In standby mode elSB 0 00025 kW Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic roo...

Reviews: