background image

30 

Alignment of the ambient temperature 

 
This  function  is  used  to  edit  the  ambient 
temperature  measured  by  the  radiator 
and  used  to  manage  heating  power,  if  it 
needs to be  corrected to compensate  for 
reading  errors  due  to  things  like  being 
near  to  heat  sources,  or  cold  air 
draughts.  

 

The  display  flashes  the  correction  value 
to be applied.  To edit it, push the “+” or “-
“ keys. 
 

 

 

If,  for  example,  the  temperature  set  on 
the  radiator  is  19,2°C  and  the  ambient 
temperature is measured at 19,5°C, align 
it by +0,3°C.  

 

  Always  wait  at  least  4  hours  for  the 

temperature  to  settle,  before  doing  any 
alignment. 

Remote control 

 
This  function  allows  the  radiator  to  be 
controlled  using  external  timers,  piloted 
sockets  with  telephonic  control,  and 
similar devices. 
 
For further details see paragraph 6.3.3. 

 

Switching  the  function  (ON)  or  (OFF)  is 
done  by  pushing  the  “+”  or  “-“  keys 
respectively. 
 

 

 
Warning:  Activation  is  NOT  indicated  by 
any icon on the display. 

 

6.3.1 Presence sensor 

This function allows the radiator  to pick up whether or not people are in the space, and automatically regulate the heating 
level, in order to optimise comfort and energy saving. 
Thanks to this function, which can only be activated in Comfort mode, the radiator continuously monitors the room and, if no 
people are detected, it reduces the comfort temperature set as follows:  

 

Period 

of absence 

Reduction of the Comfort 

temperature 

Indication 

on the display 

60 min 

1,0°C 

The  presence  sensor  and  comfort  mode 
symbols flash together  

 

 

 

((   

    ))

 

90 min 

2,0°C 

120 min 

3,5°C 

38 hours 

Anti-freeze activated 7±3°C 

 

The  reduction  is  temperature  always  relates  to  the  comfort  temperature.    If  the  radiator  is  in  Eco  or  Anti-freeze  mode,  no 
change in temperature to be maintained in the room will be observed.  
Should someone be detected in the room for at least 10 consecutive minutes, the temperature is automatically returned to 
the comfort temperature set, without any reduction.  The same happens if, while the temperature required is being reduced, 
due to an absence of people being detected in the room, the "M" key is pushed.  
Important: 
Correct  operation  of  this  function  may  depend  on  where  the  radiator  is  positioned  in  the  room.      To  choose  the  best 
installation  position,  bear  in  mind  that  the  sensor  detects  movements  within  the  area  indicated  in  figure  9,  and  that  no 
objects must be in its  way.  Presence  detection is also more  effective  when  people move in  front  of  the sensor  that  when 
they move towards it.  

 

Summary of Contents for KLIMA Series

Page 1: ...e consultazioni GB Please retain these instructions in a safe place for future reference FR Conserver cette notice pour toute consultation ult rieure RO Pastrati instructiunile pentru consultari ulter...

Page 2: ...2 n 1 n 1 n 4 5x60mm n 4 8x50mm 1 4 mm 2 3 4 min 15cm min 15cm min 15cm min 50cm min 15cm 1 1 3 3 2 2 4 4...

Page 3: ...3 6 8 7 click 5 click A B...

Page 4: ...4 9 3m 1m 4m 3m...

Page 5: ...r mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children...

Page 6: ...wn in figure 4 Rest the bracket on the floor to use it as a template to mark the points a which the two lower fixing holes are to be made figure 5A Lift the bracket until its lower fixing points coinc...

Page 7: ...unction controlled by the key pushed 6 2 2 Switching the radiator on and off The power supply to the radiator is controlled by a two pole electromechanical switch G located on the right side of the ra...

Page 8: ...ode to Comfort mode Icon Description When used Comfort When at home The radiator works to maintain the comfort temperature set Eco When you are away from home for short periods from 2 to 48 hours or y...

Page 9: ...mes by going to Comfort mode first using the M key and then selecting the value required using the and keys Please note In Pilot Wire mode the Eco temperature is always equal to the Comfort temperatur...

Page 10: ...ing saved the date and time this setting procedure will be activated automatically 6 2 6 Customizing P1 Program Program P1 may be modified to suit the users needs Modification of P1 gives the user the...

Page 11: ...ation involves the period of time between 23 00 and 00 00 Having modified the temperature for each of the 23 hours of Day 1 press further button to enter the modification mode of Day 2 Press button to...

Page 12: ...esult will be the cancellation of the display modification procedure and will restore back the factory default settings During the programmation process the heating elements will automatically switch...

Page 13: ...ay directly Day 3 Wednesday Repeat the procedure previously described until D 6 appears on the display Since we don t want to modify Day 6 and 7 we can exit the Program settings mode holding F and pre...

Page 14: ...e by pushing the or keys respectively Activation is indicated by the relevant icon that switches on on the display Daily consumption This function makes it possible to view the power the radiator has...

Page 15: ...aving Thanks to this function which can only be activated in Comfort mode the radiator continuously monitors the room and if no people are detected it reduces the comfort temperature set as follows Pe...

Page 16: ...er being interrupted for more than 30 minutes when it is switched on Stand by mode is not set as normally happens by Comfort mode starts immediately The comfort temperature is as set before the power...

Page 17: ...raughts The temperature in the room differs from the temperature set Having waiter for the ambient temperature to stabilise for at least 4 hours you may have to compensate for any differences between...

Page 18: ...In standby mode elSB 0 00025 kW Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic roo...

Reviews: