background image

24 

 

                                               00:00                                                                  17:00                     24:00 

Monday-Thursday 



 

Friday 

 



 

Saturday-Sunday 



 

 

 

             

                              00:00                      07:00                                        18:00              24:00 

Monday-Friday   



 

Saturday-Sunday 



 

 

 

= temperature "COMFORT"    

= temperature "ECO"  

= temperature anti-freeze 

 

 
The program P1 can be customized following the instructions listed in paragraph 6.2.6. 
The  programmes  P2  and  P3  are  preset  and  cannot  be  changed,  other  than  in  the  case  of  comfort  and  eco  temperature 
values.   
 
To set the temperatures (valid for all programmes):  
- Select Comfort operating mode and set the relevant temperature.  
- Select Eco operating mode and set the relevant temperature. 
- Select the programme required P1, P2 or P3. 

Please  note

:    When  you  select  programme  P1  without  ever  having  set  the  current  date  and  time,  the  system  will 

automatically switch to the regulation mode explained in paragraph 6.2.5.  
 

6.2.3.2 Using the pilot wire 

If a connection cable is supplied without a plug, the radiator can also be controlled using specific programmers.   
The  comfort  temperature  used  in  Pilot  Wire  mode  is  set,  as  already  explained  for  the  preset  programmes,  by  going  to 
Comfort mode first, using the "M" key and then selecting the value required using the "+" and "-" keys.  
Please note: In Pilot Wire mode, the Eco temperature is always equal to the Comfort temperature less 3,5°C. 
 

6.2.4 Setting the temperatures 
 

The  radiator  is  characterised  by  2 
reference temperatures, comfort and eco, 
which can be set independently. 

 

► 

 

 

An arrow to the right of the display moves 
along  a  scale  from  green  to  red  to 
indicate  whether  the  temperature  differs 
more  or  less  from  the  recommended 
value of 19°C.  

The preset comfort temperature is 19,0°C 
and  can  be  changed  using  the  “+”  o  “-“ 
keys.  
 

 

 

 

If  the  comfort  temperature  is  set  at  a 
value  lower  than  the  eco  temperature, 
the  latter  is  automatically  reset  at  the 
comfort value - 0,5°C.  

The  preset  eco  temperature  is  15,5°C 
and  can  be  cha

nged  using  the  “+”  or  “-“ 

keys. 
 

 

 

 

The  recommended  difference  between 
the  comfort  and  eco  temperature  values 
is 3,5°C.  If the difference set  differs from 
the  suggested  value,  the  eco  symbol 
changes as follows:  

 

  

→  

 

 
The  maximum  value  that  can  be  set  for 
the  eco  temperature  is  equal  to  the 
comfort temperature value - 0,5°C. 

If the ambient temperature is lower than the temperature required and displayed, the heating indicator switches on, on the 

display

 

 

Summary of Contents for KLIMA Series

Page 1: ...e consultazioni GB Please retain these instructions in a safe place for future reference FR Conserver cette notice pour toute consultation ult rieure RO Pastrati instructiunile pentru consultari ulter...

Page 2: ...2 n 1 n 1 n 4 5x60mm n 4 8x50mm 1 4 mm 2 3 4 min 15cm min 15cm min 15cm min 50cm min 15cm 1 1 3 3 2 2 4 4...

Page 3: ...3 6 8 7 click 5 click A B...

Page 4: ...4 9 3m 1m 4m 3m...

Page 5: ...r mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children...

Page 6: ...wn in figure 4 Rest the bracket on the floor to use it as a template to mark the points a which the two lower fixing holes are to be made figure 5A Lift the bracket until its lower fixing points coinc...

Page 7: ...unction controlled by the key pushed 6 2 2 Switching the radiator on and off The power supply to the radiator is controlled by a two pole electromechanical switch G located on the right side of the ra...

Page 8: ...ode to Comfort mode Icon Description When used Comfort When at home The radiator works to maintain the comfort temperature set Eco When you are away from home for short periods from 2 to 48 hours or y...

Page 9: ...mes by going to Comfort mode first using the M key and then selecting the value required using the and keys Please note In Pilot Wire mode the Eco temperature is always equal to the Comfort temperatur...

Page 10: ...ing saved the date and time this setting procedure will be activated automatically 6 2 6 Customizing P1 Program Program P1 may be modified to suit the users needs Modification of P1 gives the user the...

Page 11: ...ation involves the period of time between 23 00 and 00 00 Having modified the temperature for each of the 23 hours of Day 1 press further button to enter the modification mode of Day 2 Press button to...

Page 12: ...esult will be the cancellation of the display modification procedure and will restore back the factory default settings During the programmation process the heating elements will automatically switch...

Page 13: ...ay directly Day 3 Wednesday Repeat the procedure previously described until D 6 appears on the display Since we don t want to modify Day 6 and 7 we can exit the Program settings mode holding F and pre...

Page 14: ...e by pushing the or keys respectively Activation is indicated by the relevant icon that switches on on the display Daily consumption This function makes it possible to view the power the radiator has...

Page 15: ...aving Thanks to this function which can only be activated in Comfort mode the radiator continuously monitors the room and if no people are detected it reduces the comfort temperature set as follows Pe...

Page 16: ...er being interrupted for more than 30 minutes when it is switched on Stand by mode is not set as normally happens by Comfort mode starts immediately The comfort temperature is as set before the power...

Page 17: ...raughts The temperature in the room differs from the temperature set Having waiter for the ambient temperature to stabilise for at least 4 hours you may have to compensate for any differences between...

Page 18: ...In standby mode elSB 0 00025 kW Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic roo...

Reviews: