6.4.2. Diagnostics – Logs
Fig. 6.20: Configuration menu Diagnostics – Logs
Shows internal station logs. Individual tabs allow total or filtered view.
When you first open the screen, it is necessary to start browsing logs by pressing the Refresh button.
Listings of all logs can be filtered. You can enter text in the upper left corner window for filtering listings.
For example, you want to know when was the configuration of the station modified: On the Local events
screen, enter “Configuration” and hit Enter.
You can use plain text or regular expressions for filtering (JavaScript format).
Displays the last 3 records from all types of logs.
Overall
Events from Local or Peer station.
Local events, Peer events
History of modulation switching if ACM is enabled. Local and Peer
station.
Local ACM, Peer ACM
Alarms from Local or Peer station.
Local alarms, Peer alarms
Maximum length of displayed logs is 250 entries. If you need to display longer history, use of CLI interface
is needed.
87
© RACOM s.r.o. – RAy Microwave Link
Configuration