Station continuously stores information about the values of important variables:
Temperature inside the station
Instantaneous value of temperature inside the station. Measured
on the modem board. Temperature of radio board is available via
SNMP.
Supply voltage
Instantaneous value of station supply voltage.
RSS
Received signal strength.
SNR
Signal-to-noise ratio of the received signal.
BER
Instantaneous bit error rate on link.
Net bitrate
Instantaneous transmission capacity.
Ethernet in throughput
Instantaneous speed (20s average) of incoming user data on the
user Ethernet port.
Ethernet out throughput
Instantaneous speed (20s average) of outgoing user data on the
user Ethernet port.
TX power
Instantaneous value of transmission power.
The values are saved in the following resolutions and history lengths
•
Resolution 1 minute, length of history 1 week
•
Resolution 15 minutes, length of history 30 days
•
Resolution 1 day, length of history about 180 days
Stored values can be viewed using three methods:
Preview all values for the last 24 hours
Thumbnails
Detailed graphical view of one or two selected values for the given interval
Viewer
Numerical view of all values
Data
RAy Microwave Link – © RACOM s.r.o.
84