Fig. 5.22: Arkivator antenna bracket (2012) Fig. 5.23: Bracket on the mast, version 2012
A reducing adapter (part No. 25), a reducing crossplate (part No. 21) and sleeves (part No. 22) are
used for mounting the FOD unit (part No. 20) on the antenna. During installation do not forget "O" rings
(part No. 26 and 27) and to lubricate the "O" ring (part No. 27), see Section 5.2.3, “Lubrication and
preservation of the antenna pivot”.
Bolt (part No. 14) serves for accurately setting the vertical direction of the antenna. When setting the
direction release bolt (part No. 12 and 13), and then tighten it again once you have the correct position.
The nuts on bolt (part No. 10) serves for setting the horizontal direction. Once the direction is set these
nuts (part No. 11), pivot bolt (part No. 9) in the hanging eye of bolt and two pivot bolts (part No. 8)
where the tilt bracket is need to be tightened.
Fig. 5.24: Arkivator antenna bracket,
version 2013
Fig. 5.25: Arkivator antenna bracket (2013)
RAy Microwave Link – © RACOM s.r.o.
44
Installation