3155 User Manual
Performance Verification 5-4
2.
Set the DMM to ACV measurements (RMS).
3.
Connect the Model 3155 output to DMM input. Termi-
nate the output with a 50O feedthrough termination. Set
the amplitude and verify DMM reading as follows:
3155 SETTING
DMM READING
7.50 V
2.682 V – 2.622 V
750.0 mV
268.2 mV – 262.2 mV
DC Offset Charac-
teristics
Accuracy Specifications
:
±
(1% of r1% of amp200µV),
±
400mV window
±
(1% of r1% of amp2mV),
±
4V window
Equipment
:
DMM, 50O feedthrough termination
1.
Configure the Model 3155 as follows:
Function:
Sine
Frequency:
1.000 MHz
Amplitude:
1 V
Remote Commands: :RES
:OUTP ON
:FUNC SIN
:FREQ 1e6
:VOLT 1
:VOLT:OFFS 2.5
2.
Set the DMM to DCV measurements
3.
Connect the Model 3155 output to the DMM input. Ter-
minate the output with a 50O feedthrough termination.
Set the Model 3155 offset and verify the DMM reading
as follows:
OFFS SETTING
DMM READING
±
2.500 V
±
2.537 V to
±
2.463 V
4.
Change the Model 3155 AMPL setting to 100 mV. Set
VOLT:OFFS and verify the DMM reading as follows:
OFFS SETTING
DMM READING
±
250.0 mV
±
253.7 mV to
±
246.3 mV
Summary of Contents for 3155
Page 4: ...This page was left intentionally blank...
Page 14: ...User Manual 3155 1 2 Overview Figure 1 1 3155 Series...
Page 41: ...User Manual 3155 Installation 2 15 Figure 2 15 Device Manager...
Page 44: ...User Manual 3155 2 18 Installation Figure 2 19 Customer Information Step...
Page 110: ...User Manual 3155 3 58 ArbConnection This page was left intentionally blank...
Page 150: ...User Manual 3155 Programming Reference 4 40...
Page 184: ...User Manual 3155 Programming Reference 4 74 This page was left intentionally blank...
Page 202: ...User Manual 3155 Specifications A 8 This page was left intentionally blank...