APPLy:DC{<%_ampl>}
Purpose
This command is a high-level command that programs the 3155 to output a DC level along with its associ-
ated parameter
•
<%_ampl> sets the output level as percentage of the amplitude setting
Parameter type
Numeric
Parameter range
<%_ampl> -100 to +100 in units of %
APPLy:DC?
Response to query version
The 3155 returns <%_ampl>. Default values are
100
APPLy:USER{<seg# >,<sclk>,<ampl>,<offs>}
Purpose
This command is a high-level command that programs the 3155 to output user-defined waveform along with
its associated parameters
•
<seg# > selects the active segment number
•
<sclk> sets the sample clock frequency in units of samples per second
•
<ampl> sets the output amplitude in units of Volts
•
<offs> sets the output offset in units of Volts
Parameter type
Numeric
Parameter range
<seg#>
1 to 4096
<sclk>
10e-6 to 100e6
<ampl>
80e-3 to 8
<offs>
-3.6 to +3.6
APPLy:USER?
Response
The 3155 returns <seg#>,<sclk>, <ampl>,<offs>. Default values are 1,10e6,5,0
FM{OFF|ON|0|1}
Purpose
This command turns the FM function on and off.
•
ON or 1 turns the FM function on
•
OFF or 0 turns the FM function off
Parameter type
Boolean
Summary of Contents for 3155
Page 4: ...This page was left intentionally blank...
Page 14: ...User Manual 3155 1 2 Overview Figure 1 1 3155 Series...
Page 41: ...User Manual 3155 Installation 2 15 Figure 2 15 Device Manager...
Page 44: ...User Manual 3155 2 18 Installation Figure 2 19 Customer Information Step...
Page 110: ...User Manual 3155 3 58 ArbConnection This page was left intentionally blank...
Page 150: ...User Manual 3155 Programming Reference 4 40...
Page 184: ...User Manual 3155 Programming Reference 4 74 This page was left intentionally blank...
Page 202: ...User Manual 3155 Specifications A 8 This page was left intentionally blank...