![background image](http://html2.mh-extra.com/html/racal-instruments/3151/3151_user-manual_3124279083.webp)
3151 And 3151A User Manual
SCPI Command Reference 4-9
Common Commands
Common Commands
Parameter Form (Default in Bold
Parameter Form (Default in Bold))
IEEE-STD-488.2
IEEE-STD-488.2
*CLS
Confirmed
*ESE
(0;0;255)
Confirmed
*OPC
Confirmed
*RST
Confirmed
*SRE
(0;0;255)
Confirmed
*TRG
Confirmed
*ESE?
Confirmed
*ESR?
Confirmed
*IDN?
Confirmed
*OPC?
Confirmed
*SRE?
Confirmed
*STB?
Confirmed
*TST?
Confirmed
Output
Configuration
Command Summary
Output Configuration commands control the output function, shape,
frequency, amplitude, filter and state. Optional modes are omitted
from these commands. Factory defaults after *RST are shown in bold
typeface. Parameter low and high limits are given where applicable.
Use the Standard Waveform parameters as described in Using The
APPLy Command.
Commands and Parameters
(Low Limit,High Limit,Default)
[SOURce:]
APPLy:SINusoid {<frequency>,[<amplitude>,[<offset>,[<phase>,[<power>]]]]}
APPLy:TRIangle {<frequency>,[<amplitude>,[<offset>,[<phase>,[<power>]]]]}
APPLy:SQUare {<frequency>,[<amplitude>,[<offset>,[<duty_cycle>]]]}
APPLy:PULSe {<frequency>,[<amplitude>,[<offset>,[<delay>,[<high_time>
,[<rise_time>,[<fall_time>]]]]]]}
APPLy:RAMP {<frequency>,[<amplitude>,[<offset>,[<delay>,[<rise_time>
,[<fall_time>]]]]]}
APPLy:SINC {<frequency>,[<amplitude>,[<offset>,[<number_cycles>]]]}
APPLy:EXPonential {<frequency>,[<amplitude>,[<offset>,[<exponent>]]]}
APPLy:GAUSsian {<frequency>,[<amplitude>,[<offset>,[<exponent>]]]}
APPLy:DC {<percent_amplitude>}
APPLy:USER {<segment_number>,[<sampling_clock>,[<amplitude>, [<offset>]]]}
APPLy:<function_shape>?
APPLy?
FUNCTion:MODE {FIXed | USER | SEQuence}
(FIX)
FUNCTion:MODE?
FUNCtion:SHAPe {SINusoid | TRIangle | SQUare | PULSe | RAMP | SINC
EXPonential | GAUSsian | DC }
(SIN)
FUNCtion:SHAPe?
FREQuency {<frequency> | MINimum | MAXimum}
(100E-6,50E6,1E6)
FREQuency?
FREQuency:RASTer {<frequency> | MINimum | MAXimum} (100E-3,100E6,1E6)
FREQuency:RASTer?
FREQuency:RASter:SOURce {EXT | INT | ECLtrg0}
(INT)
Summary of Contents for 3151
Page 4: ...This page was left intentionally blank...
Page 24: ...3151 And 3151A User Manual Getting Started 1 12 This page was left intentionally blank...
Page 29: ...3151 And 3151A User Manual Configuring The Instrument 2 5 Figure 2 1 Set The Logical Address...
Page 74: ...3151 And 3151A User Manual Using The Instrument 3 44 This page was left intentionally blank...
Page 98: ...3151 And 3151A User Manual SCPI Command Reference 4 24 This page was left intentionally blank...
Page 127: ...3151 And 3151A User Manual Optional Harness Assemblies 6 3...
Page 131: ...3151 And 3151A User Manual Optional Harness Assemblies 6 7...