Publication No. 980855 Rev. A 1256 User Manual
EADS North America Test and Services SCPI Command Basics 5-29
MOD:DEF
A12345678901,8
Assigns name to plug-in module 2:
MOD:DEF ZZZZZZ2,2
Examples of invalid commands are as follows.
Incorrect; the module name must appear first:
MOD:DEF
5,ABCD
Incorrect; the module name must begin with a letter:
MOD:DEF
4ASDF,8
Incorrect (for SCPI compatibility only); the module name is 13
characters long and it must be
≤
12:
MOD:DEF A123456789012,5
The following examples show how to use module names in place
of plug-in addresses.
Assigns the name
matrix
to plug-in 5:
MOD:DEF
matrix,5
Closes row 0, column 23 of
matrix
:
CLOSE
(@matrix(23))
Assigns the name
Power
to module 6:
MOD:DEF Power,6
Close
Power
relay channels 7 through 12:
CLOSE (@Power(7:12))
Closes relays on two modules:
CLOSE (@Power(8),matrix(102:104))
Removing Module
Names
The MODULE:DELETE command may be used to delete a single
plug-in module name from the list of known module names. The
MODULE:DELETE:ALL command may be used to remove all
presently defined module names.
The syntax for these commands is:
[:ROUTe]
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com