![background image](http://html2.mh-extra.com/html/racal-instruments/1256/1256_manual_3131895044.webp)
Publication No. 980855 Rev. A 1256 User Manual
EADS North America Test and Services Using the Front-Panel Controls 3-9
1. Press the top key next to the display. This selects the top
display line so that you can change it. The selection markers
“>” and “<” appear on the line to indicate that it is selected.
Rotate the knob until the top line reads:
>----OPERATIONS----<
2. Select line 2 (next to the top line) by pressing the second
key. This selects line 2 so that you may select the slot to
work with:
----OPERATIONS----
>Slot 01: 1260-121A <
Channel: 0
Status: Open
3.
Rotate the knob until line 2 indicates the contents of slot 3:
----OPERATIONS----
>Slot 03: 1260-118 <
Channel: 0
Status: Open
4. Press the third key to select line 3 of the display (channel
number):
----OPERATIONS----
Slot 03: 1260-118
>Channel: 0 <
Status: Open
5.
Rotate the knob until line 3 shows the desired relay channel
number, which in this example is 4:
----OPERATIONS----
Slot 03: 1260-118
>Channel: 4 <
Status: Open
6. Press the fourth key to select line 4. Rotate the knob until
the display reads:
----OPERATIONS----
Slot 03: 1260-118
Channel: 4
<Set to?: Closed
7. Press the fourth key to confirm the closure of the relay
channel. The relay then closes, and the display indicates the
updated status on line 4:
----OPERATIONS----
Slot 03: 1260-118
Channel: 4
> Status: Closed <
Opening a Relay
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com