BATTERY AND BATTERY CHARGE 

1. Battery 

Charge the equipped battery before using it, although it has already charged and can be used. 

 

Notes : 1.  Be sure to make correct connection with the battery terminals (

red, 

black). 

2. To connect the battery, start with the 

terminal, to disconnect it, start with the 

terminal. 

 

2. Battery Care 

(1)  The battery electrolyte is diluted sulfuric acid and is very harmful to the skin. Never unscrew the electrolyte cap except 

when required to refill. When refilling, pay enough attention to keep the electrolyte off the skin. Also, never to spill the 
electrolyte. 

(2)  The battery discharges continuously even not in use, so the supplementary charging is required. 

* Be sure to recharge the battery using the attached charger, because unlike automobile batteries, this battery cannot be 

charged during the operation. 

(3)  The attached charger is an automatic charger, which can automatically switch from the normal charging to the 

supplementary charging (charging to cover the self-discharged electricity). 

(4)  Check the electrolyte level from time to time. Put distilled water into the battery up to the maximum liquid level, if the 

electrolyte level is below the level. 

 

3. Battery Charging 

(1)  Clean the battery terminals, by removing dust and dirt from the 

battery. If the electrolyte level is below the maximum liquid level, 
put distilled water into the battery up to the maximum liquid level. 

(2)  Connect the output plug of the battery charger to the socket of 

this fire fighting pump. If the power switch is tuned on, the power 
lamp(red) is lit and the charging starts. 

(3)  The charging is complete when the completion lamp(green) is lit 

and the power lamp(red) is turned off. The charger goes into the 
supplementary battery charging. 

 

Notes : 1. The breaker is activated if excessive current is supplied because of a reverse connected battery. Also, the 

breaker may be activated if the Main Switch is turn to the "CELL" during the charging. Eliminate the causes 
of the problem, and reset the breaker to the normal position. 

2. The useful life of the battery is about 2 years. 

 

 

 

 

Charge status

 

Lit

 

 

Power lamp

(Red)

 

Completion 
lamp (Green)

Not charged 

 

 

 80% 

 

 

Normal 
charging

 

 80% 

 

○ 

Compensation charging

 

 

○ 

WARNING 

WARNING 

WARNING 

Summary of Contents for P455SM

Page 1: ...PORTABLE FIRE FIGHTING PUMP P455 P476 P555 P572S INSTRUCTION MANUAL WARNING BE SURE TO READ THIS MANUAL BEFORE OPERATION S M S M S M...

Page 2: ......

Page 3: ...ion and maintenance of the pump please contact the maintenance shops or special dealers who have been qualified for maintenance of the portable fire fighting pumps This instruction manual is intended...

Page 4: ...get fire 1 Perform operation at a place 3 m or more off any inflammables 2 Never perform operation on dry grass If it is inevitable remove dry grass under the muffler 3 When you take off battery cap...

Page 5: ...n of the discharge valve Scattering of stones and explosion etc Attention 1 Pay full attention to stones or other foreign matters which may cause physical risk during water discharge 2 Never suck or d...

Page 6: ...ge turbine pump Suction port dia mm Nominal 75 fire fighting screw type fitting JIS B 9912 Discharge port dia mm Nominal 65 fire fighting screw type fitting JIS B 9912 Rated pressure MPa kg cm2 0 55 5...

Page 7: ...ge turbine pump Suction port dia mm Nominal 75 fire fighting screw type fitting JIS B 9912 Discharge port dia mm Nominal 65 fire fighting screw type fitting JIS B 9912 Rated pressure MPa kg cm2 0 55 5...

Page 8: ...e turbine pump Suction port dia mm Nominal 75 fire fighting screw type fitting JIS B 9912 Discharge port dia mm Nominal 65 fire fighting screw type fitting JIS B 9912 Rated pressure MPa kg cm2 0 70 7...

Page 9: ...stage turbine pump Suction port dia mm Nominal 75 fire fighting screw type fitting JIS B 9912 Discharge port dia mm Nominal 65 fire fighting screw type fitting JIS B 9912 Rated pressure MPa kg cm2 0...

Page 10: ...terminal Detach the liquid port plug nearest to the terminal of the battery and mount the battery liquid level sensor Exhaust Manifold Cylinder Drain Cock Ignition Plug Cover Vacuum Pump Air Exhaust...

Page 11: ...When carrying the pump be sure to hold it correctly with the carrying handle 3 Set the pump as near as possible to a water suction level so as to minimize suction height Place the pump as level as pos...

Page 12: ...full 4 Never start and stop the engine repeatedly without water suction Fuel mixture remaining unburnt may cause explosion after fire 2 Water discharge 1 After engine startup set the water suction le...

Page 13: ...t the water feeding pressure of the master pump so that the compound pressure gauge of the slave pump in operation will read 0 05 to 0 1 MPa max 0 6 MPa The slave pump will not run if the compound pre...

Page 14: ...erflow bottle Refer to the photo of the next page for overflow bottle 5 Attach the suction port cap and cover the pump before storage Notes 1 Incomplete water drain may cause damage due to freezing or...

Page 15: ...s drained completely release your hand from the knob 4 Dispose of drained fuel in the bottle Wipe out spilt fuel if any with waste cloth Enough care should be taken of disposal of the waste cloth 5 Re...

Page 16: ...e battery discharges much Be sure to check the battery level PUMP 1 Water Suction Port Strainer After the pump is operated for water containing alga clear the alga of the water suction strainer 2 Vacu...

Page 17: ...ock opens LED goes on Close drain cock except in drain ON LED goes on if cooling water pressure is low Insufficient engine cooling water may cause over heating Increase water pressure by setting throt...

Page 18: ...electricity 4 Check the electrolyte level from time to time Put distilled water into the battery up to the maximum liquid level if the electrolyte level is below the level 3 Battery Charging 1 Clean...

Page 19: ...e pressure does not become negative confirm that the suction port cap drain cock etc are tightly closed and repeat the procedure mentioned before 3 Cover the cooling water discharge port with your pal...

Page 20: ...h a new one Electric system Others Set the main switch to RUN and confirm that LED of Rabbit monitor battery voltage display goes on If it is on charge the battery only in S specification Difficult st...

Page 21: ...elt Confirm that the water suction pipe is regularly tightened and that the water suction portion is regularly placed in water If not tighten the water suction pipe regularly and immerse the water suc...

Page 22: ...AGRAM S WIRING DIAGRAM Notes 1 This pump is equipped the fuse but pay attention to correct connection with and terminals of battery 2 In connection with the battery start with In disconnection start w...

Page 23: ...21 M WIRING DIAGRAM...

Page 24: ...L82900940 1 2013 03 50K...

Reviews: