OPERATION
1. When AC power is applied, the charging indicator light is
illuminated, indicating that the
BATTERY
is being charged.
2. When power fails, the standby power automatically
switches to emergency power (internal battery), operating
at reduced illumination. Not all LED boards will illuminate
with standby power. The emergency driver supplies 25W of
power in standby power for a minimum of 90 minutes.
3. When AC power is restored, the emergency driver
automatically returns to charging mode.
Although no routine maintenance is required to keep the
emergency driver functional, it should be checked periodically
to ensure that it is working. The following schedule is
recommended:
1. Visually inspect the charging indicator light monthly. It
should be illuminated.
2. Test the emergency operation of the fixture at 30-day
intervals for a minimum of 30 seconds.
3. Conduct a 90-minute discharge test once a year. Fixture
would operate at reduced illumination for a minimum of
90 minutes.
TROUBLESHOOTING
MAINTENANCE
1.
Is the fixture grounded properly?
2.
If the charging indicator light does not illuminate after
pressing the test button, check if battery is connected
properly.
BATTERY BACKUP MODELS
WIRING
CAUTION: FOR BATTERY BACKUP FIXTURE
. Voltage could be
present in
BATTERY
. To prevent high voltage from being present
on output leads, inverter connector must be open. Do not join
BATTERY
connector until installation is complete and AC power is
supplied to the emergency driver
(Fig. 11)
.
NOTE:
Make sure that the necessary branch circuit wiring is
available. An
UNSWITCHED
AC source of power is required. The
emergency driver must be fed from the same branch circuit as the
LED driver.
CAUTION:
Do not use any supply voltage other than 120-277V
50/60 HZ.
1. Connect
UNSWITCHED HOT
fixture lead to
HOT
AC supply line.
2. If using an
UNSWITCHED
circuit, connect
UNSWITCHED
and
SWITCHED
lines together.
3. If using a
SWITCHED
circuit, connect
SWITCHED HOT
AC fixture
lead to the external
SWITCHED
.
4. Connect the
NEUTRAL
fixture lead to the
NEUTRAL
supply line.
5. For 0-10V Dimming, connect
DIM (+)
and
DIM (-)
to the supply
DIM (+)
and
DIM (-)
.
6. Connect
GROUND
lead from the fixture to the supply ground.
Do not connect
GROUND
to the output leads.
7. All unused lead must be capped and insulated.
8. After installation is complete, supply AC power to the fixture
and connect the
BATTERY
.
9. When power is on, the fixture should be on and the Charging
Indicator Light should illuminate to indicate the battery is
charging.
10. Once the
BATTERY
has charged for at least one hour, a short
duration test may be performed by pressing the test button.
11. After the battery has charged for 24 hours, a long duration test
can be performed by shutting power to the fixture.
LIGHT
FIXTURE
INSIDE FIXTURE
BATTERY
Pink (or Gray)/DIM–
Black/Switched Line
Green/Ground
White/Neutral
Black/Unswitched Line
Purple/DIM+
BACKUP
DRIVER
BATTERY
CONNECTOR:
CONNECT
ONLY AFTER
AC SUPPLY
POWER IS
CONNECTED
Fig: 11
SHARK 2FT 4FT IN 1221
Easy Answers
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
Answered promptly - [email protected]
Free Lighting Layouts
Answered online or by request
© 2022 RAB LIGHTING Inc.
73674-RAB