background image

INSTRUCTIONS

 

SHARK

®

 INSTALLATION

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install

 

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

TROUBLESHOOTING

1.  Check that the line voltage at the fixture is correct. Refer to 

wiring directions.

2.  Is the fixture grounded properly?

CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough to touch.  

Do not clean or maintain while fixture is energized.

1.  Lens should be washed in a solution of warm water and 

any mild, non-abrasive household detergent, rinsed with 

clean water and wiped dry.

 

WARNING: Polycarbonate is affected by cleaning agents 

or other liquids containing partial solvents such as 

low molecular weight aldehydes and ethers, ketones, 

esters, aromatic hydrocarbons and perchlorinated 

hydrocarbons. In addition, chemical attack ranging from 

partial to complete destruction of polycarbonate occurs 

in contact with alkalines, alkali salts, amines and high 

zone concentrations. Please go to rablighting.com for a 

detailed list of damaging chemicals.

2.  Do not open fixture to clean the LED. Do not touch the LED. 

PINK (or GRAY)

LIGHT

FIXTURE

Vaux 12V

YELLOW

GROUND

GROUND

( - ) DIM V

( + ) DIM V

COMMON

LINE

BLACK

WHITE

PURPLE

Fig:10

0-10V DIMMABLE WIRING

Universal voltage driver permits operation at 120V thru 277V, 
50 or 60 Hz. Units ordered with 

(/480V) 

suffix are 480V, 50Hz or 

60Hz. For 0-10V Dimming follow the wiring directions as shown 
in Fig. 10.
1.  Connect the black fixture lead to the  

LINE 

supply lead.

2.  Connect the white fixture lead to the

 COMMON

 supply 

lead.

3.  Connect the

 GROUND 

wire from fixture to supply ground. 

Do

 NOT

 connect the

 GROUND

 of the dimming fixture to 

the output.

4.  Connect the purple fixture lead to the (V+) DIM lead.
5.  Connect the pink 

(or gray)

 fixture lead to the (V-) DIM lead.

6.   Cap the yellow fixture lead, if present. Do NOT connect.

ANGLE SURFACE MOUNTING

Angle Surface Mounting Brackets Fig. 8  

(

ANGSHARK-G2 ordered separately) 

1.  Use appropriate mounting hardware 

(not supplied)

 to secure 

the 

Angle Bracket

 (ANGSHARK-G2) (2)

 to mounting surface as 

shown in Fig. 8.

2.  Recommended 

Angle Bracket 

distance center to center is      

12 7/8” for SHARK 2ft and 36 13/16” for SHARK 4ft.

3.  Secure 

Surface Mounting Brackets

 (2) 

to 

Angle Bracket

 (2) 

with 

Screws

 provided.

4.  Snap 

Housing

 on 

Surface Mounting Brackets 

(2) 

as shown in 

Fig. 9

.

Fig: 8

Fig: 9

 Angle 

Bracket 

(2)

Housing

Screw

Surface 

Mounting 

Brakets

Mounting 

Surface

Reviews: