10. Maintenance Procedures
This section provides general maintenance information and electrical adjustment for
the HC5-10 hybrid coupler.
Warning! When the coupler is in function, inside are present dangerous voltages,
elevated currents, and are presents RF signals of strongly power.
Don’t remove any cover without switching off the system first and close all covers
before restarting the system.
Ensure all primary power is disconnected from the amplifier before attempting
equipment maintenance.
10.1
Routine Maintenance
The only regular maintenance needed by HC5-10, is the periodic substitution of the
blowers, and the cleaning of dust filters and any dust accumulated inside the amplifier.
The time between overhauling of the blowers depends upon several environmental
factors, temperature, humidity, dust pollution etc.
It’s advisable to check the unit every 6 months, and to substitute noisy blowers.
Blowers should be changed as a matter of course at least not beyond the 35000
hours of job.