R-sensors LLC
Bldg. 1, 4, Likhachevsky proezd, Dolgoprudny, 141701, Russia
+7 (498) 744-69-95,
NDAS-N. User Manual.
60
○
Cable delay correction is a correction for a cable length measured in nanoseconds. This
correction compensates for the time delay when the NDAS-One device is connected using
a long cable.
Fig. 12.5. NDAS One Manager module. Setting of dynamically connected ports
Accordance of hardware ports and NJSP ports by default:
USB Port 1
10001
USB Port 2
10002
NDAS Port 1
10003
NDAS Port 2
10004
●
Dynamic port pool
This option configures the dynamic port pool. When the NDAS-One device is connected via a USB
hub, it will be assigned a dynamic NJSP port out of the free port pool. The port number is linked to the
serial number of the device so that the same port number will be used when reconnecting.
○
Start port number – start port number of the address pool
○
Pool size – number of ports in the pool
○
Current allocation list – current list of assigned ports
○
Clear – the button to clear the current list of assigned ports