NDAS-N. User Manual.
59
●
USB Ports
The following settings are available for USB ports:
○
Enable – activating the port.
○
NJSP Server port number – NJSP port number associated with that port.
Note that this setting does not control whether the port itself is enabled/disabled – it
determines whether the NDAS One Manager module will access this port to locate the
NDAS-One device. If you use a port to connect other devices, disable NDAS One Manager
through this configuration.
Fig. 12.4. NDAS One Manager module. NDAS ports settings
●
NDAS Ports (if available)
The following settings are available for NDAS ports:
○
Enable – activating the port.
○
NJSP Server port number – NJSP port number associated with that port.
○
Sync device with local clock is an option enabling synchronization of the connected
device from the NDAS-RT clock.
Note: if the device has already been synchronized with its own GPS receiver before
connecting to NDAS-RT or before enabling this option in the module settings, then the
resynchronization will not be done. In this case you must reboot the device to reset the
synchronization.