R-sensors LLC
Bldg. 1, 4, Likhachevsky proezd, Dolgoprudny, 141701, Russia
+7 (498) 744-69-95,
NDAS-N. User Manual.
40
8.2. Module configuration page
Basic configuration is performed through the module configuration web page. Click the
config
button on the module status bar to open the page. The page consists of a general
Configuration
and a
Stations list
.
The Configuration section configures the following parameters:
●
Organization
is the name of the organization (falls into the
organization
parameter of
seedlink.ini
)
●
Network code
is the code of the network (falls into the
network
parameter of
seedlink.ini
)
●
Seedlink TCP Port
is the SeedLink Server external port (falls into the
port
parameter
of
seedlink.ini
displaying
18000
by default)
●
Use custom streams.xml file
is an option controlling
streams.xml
. If this option is disabled, the
streams.xml
file is created on the basis of the stations parameters set up through the web
interface. If enabled, the user must manually create a file having the required stream parameters.
For details, see
Advanced Settings
●
Enable archiver
is an option that controls enabling of the
slarchive
program which locally
connects to the SeedLink server and saves these files in the miniSEED format
●
Archive path
is a path to the directory to which
slarchive
should save files.
Fig. 8.1. SeedLink server module. Configuration