Fireplace Installations in Covered Outdoor Locations
– FOR BASIC MILLIVOLT UNITS ONLY- NO FAN – NO LIGHTS-
Kingsman and Marquis Direct Vent fireplaces may be installed into outdoor locations provided they are suitably protected
from direct water impingement.
However, all installation clearances in the appliance manual must be observed. Framing, Clearances to
Combustibles, Mantel Heights, Facing Requirements, Venting Installation, etc.
Use supplied Safety Screen.
CAUTION – Installation of an indoor gas fireplace with an outdoor exposure is not covered under the (ANSI
Z21.88 – CSA 2.22 or ANSI Z21.50 – CSA 2.33) standard(s) used to certify the indoor gas-fired fireplace. The
Intertek safety certification will not apply to this installation method. This installation method must be deemed
acceptable by the Authority Having Jurisdiction (AHJ) prior to the indoor gas fireplace being installed.
A
Minimum
sheltering cover
(overhang) of
1/2 the distance from the base
of the fireplace to the ceiling
(base of roofline) is required.
EXAMPLE:
The bottom of the fireplace is
84”
from the ceiling.
Therefore,
42”
of sheltering cover
is required above fireplace.
All wiring connections to line
power shall be in accordance
with outdoor requirements of;
-NECA NFPA 70 in the USA
-Canadian Electrical Code, CSA
C22.1 for Canada.
Outdoor Area
(Deck)
Indoor Area
(Living Room)
⚠
NOTE: TEMPERED
GLASS WARNING:
Tempered glass is
vulnerable to rapid
and/or extreme changes
in temperature (thermal
shock). Take care to
prevent water from
contacting the fireplace,
especially if it is hot.
NOTE:
See-Through Units
are
suitable for an outdoor location,
but not on the outside wall of a
house or other structure, as air
flows through both sides of the
fireplace.
Outdoor
Area
42”
84”
96”
12”
Outdoor
Area
42”
84”
96”
12”
Glass
Door
Glass
Door
The Fireplace is not to be operated in
temperatures below freezing (0°C / 32°F).
Glass
Door
7
Summary of Contents for Kingsman FDV451LP
Page 42: ...Gas Conversion for Modulator PART C 42...
Page 47: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 47...
Page 48: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 48...
Page 55: ...Proflame 2 Remote Control 55...
Page 57: ...57...