background image

 

 

27 

 

 

Summary of Contents for RIDA QUICK SCAN

Page 1: ...27 ...

Page 2: ...ranslated into another language without our express prior written consent Subject to technical changes Brochure Manual for RIDA QUICK SCAN Version 1 0 0 Copyright 2009 by R Biopharm AG Printed in Germany R Biopharm AG An der neuen Bergstraße 17 D 64297 Darmstadt Germany Phone 49 0 6151 8102 0 Fax 49 0 6151 8102 40 email info r biopharm de ...

Page 3: ...3 Changing device settings SETUP MODE 14 3 4 Displaying stored test results MEMORY MODE 15 3 5 Calibrating the reader CALIBRATION MODE 16 3 6 External components optional 17 3 6 1 Barcode reader 17 3 6 2 Printer 19 4 Troubleshooting and fixing faults 20 5 Safety and maintenance 22 5 1 Safety information 22 5 2 Important information for using the device 23 5 3 Care and maintenance 23 5 4 Replacing ...

Page 4: ...t and precise scanning process The results are stored in the device and can be printed as required All results are stored with data such as time of measurement date operator etc The mobile reader can be connected to a power supply or can also be operated with batteries while the USB interface allows it to be connected to a PC This enables precise measurement of mycotoxin concentrations in stationa...

Page 5: ...5 2 Step one 2 1 Overview ...

Page 6: ...6 ...

Page 7: ... The printer and RIDA QUICK SCAN have different power units To switch on the reader press the middle ENTER key 3 for around 1s On the bottom of the reader you will find a diagram of the keypad and the side connections for quick reference Switch the device off again by holding the ENTER key 3 depressed for slightly longer 2 3 Making the necessary connections Insert the supplied power unit 12V DC in...

Page 8: ...the reader Both devices can be connected at the same time and can be plugged into either each of the ports You will find more information about these two components in Section 3 6 On the bottom of the device you will find a diagram of the connections and the keypad Figure 4 2 4 Basics of operation Operate the device and make selections with the and keys on the keypad 2 The active selection field i...

Page 9: ... are being recharged The batteries are recharged only when the device is switched on Figure 5 a Figure 5 b Example Cut Off Besides Scan Mode you can also choose between the following modes by pressing the keys Setup Mode Basic device function settings Memory Mode Display stored test measurements Calibration Mode Check the Calibration of the reader These modes are described in more detail below The...

Page 10: ...ith the corresponding number on the test packaging to ensure that you are using the right test batch If the numbers do not match enter the correct batch number barcode manually or scan the barcode Two options are available to change the lot number a manual method and a more convenient and safe method via a 2 D barcode The latter one is recommended Figure 7 manual input Figure 8 Enter the barcode n...

Page 11: ...ed checksum on the stick envelopes or the certificate Batch No input using the 2D barcode scanner Figure 11 Insert completely the plug in of 2 D barcode scanner in the plug of the device picture 2 and figure 4 without damaging the pins The arrow on the plug in should be on top Press enter and within a few seconds a single acoustic signal will appear Now the scanner is active and the lightening cro...

Page 12: ...hile the reader is operating and scanning a RIDA QUICK test strip the internal detector moves across the test strip Consequently during the measurement the test strip must not be moved You can see on the display when a measurement is being performed The data is then saved see also Sect 3 4 Caution When you insert the test make sure that it sits correctly and horizontally in the proper position wit...

Page 13: ...ou select Print the device automatically goes to the start of the next measurement If you do not want to print the result at that time e g no printer connected you can call it up from MEMORY MODE see Section 3 4 at a later date and print it out then In the following measurements Start Scan is selected automatically and all you have to do is press ENTER twice to perform the next measurement ...

Page 14: ...ies If a menu contains more than four parameters when you reach the bottom entry on the first page the second page with the other parameters is displayed automatically When you reach the bottom entry you can press the key to use the wrap around function The cursor then jumps to the top position of the display again This means that you do not have to scroll the entire menu to get to the top of the ...

Page 15: ...between the different measurements Record No refers to the data record currently displayed The following data records are stored Figure 15 The meaning of these parameters are as follows Record No The record number is automatically counting from 1 to 100 The internal memory must be then erased with the delete function or via the RIDA QUICK Manage Software connected with USB to a PC User ID Up to 20...

Page 16: ...e RIDA QUICK SCAN is a highly developed measuring system To ensure the high quality of the measurement results at all times it is important that you check the calibration of the reader at regular intervals This is a simple process which the reader asks you to perform automatically after a certain number of measurements 500 or a defined time 6 months For check of calibration all you need is a colou...

Page 17: ... Only when a valid calibration with the colour standard has been carried out will the measurements be stored as calibrated measurements The process checks the calibration but does not perform a calibration In case this process fails please blow of carefully any particles of the grey standard and repeat the process If the calibration control fails repeatedly please contact your supplier 3 6 Externa...

Page 18: ...ed barcode is acknowledged by an audible signal and a green light The barcode has been transferred to the measuring device The checksum is generated and shown on the display The checksum must match the number on the text strip pack If this is not the case you have to read the barcode again as the calibration parameters may not be correct If the correct checksum is not shown after you read the barc...

Page 19: ...can then let go of the key the device is switched off Because of the technology thermal printer the paper used is heat sensitive Therefore the paper must not be subjected to direct sunlight or heat for longer periods as it will discolour and make the printout illegible If it is stored in a dark and dry place e g filing cabinet or similar used for documentation the paper will keep for many years Ca...

Page 20: ...lp Press the middle key 3 on the keypad for at least one second Cause The device is in Update Mode Help Press the UP key The device changes to switch off mode Now you can switch the device on as usual see Section 3 1 Alternatively you could interrupt the power supply by removing the power unit and the batteries You can then switch the RIDA QUICK SCAN device on again as usual Fault Temperature disp...

Page 21: ...rmal printer batteries are empty Help Caution Recharge the thermal printer using the supplied power unit or operate the printer directly with the power unit CAUTION Use only the power unit supplied for the thermal printer Use of the power unit for the RIDA QUICK SCAN may damage the thermal printer Fault Although the power unit is connected to the RIDA QUICK SCAN the batteries do not recharge Cause...

Page 22: ...eplacing batteries insert them into the device with the minus pole first Figure 13 The mark on the lid of the battery compartment should help you here Do not submerge batteries in water Do not throw batteries into open flames Do not dispose of old defective batteries with normal household waste use collection points Batteries become warm when they are charging this is normal Do not operate the mea...

Page 23: ...experienced users who carry out installation and maintenance work The information should familiarise users with the care and maintenance work needed to operate a RIDA QUICK SCAN Note As the RIDA QUICK SCAN requires batteries for mobile operation these must be recharged regularly The RIDA QUICK SCAN can be recharged with the supplied 12V power unit The batteries should be recharged for at least 10 ...

Page 24: ... like those that are supplied also called mignon cells Use only nickel metal hydride NiMH batteries they last considerably longer than other types If you use other cells such as NiCd you may damage the device As opposed to nickel cadmium cells NiMH cells have almost no memory effect This allows you to operate the device in an optimum status for longer Avoid over discharging the batteries In spite ...

Page 25: ...d of the battery compartment 5 Use a flat object such as a coin Note Pay attention to the poles of the buffer battery see Figure below If the batteries are inserted wrongly the device cannot function It may also cause damage to the device Figure 13 ...

Page 26: ...00 to1060 hPa Operating conditions Temperature 15 C to 40 C Relative humidity non condensing 70 Air pressure 300 1060 hPa Protection class IP21 Housing material ABS Dimensions LxWxH 178mm x 165mm x 46mm Weight 620g Interface USB Inputs 5V to 24V level Outputs 5V level Optional components Barcode reader Power supply via RIDA QUICK SCAN Thermal printer Own battery or power unit ...

Page 27: ...27 Products from ESE GmbH are subject to quality standards according to DIN ISO 9001 R Biopharm AG An der neuen Bergstraße 17 D 64297 Darmstadt Germany Internet www r biopharm de ...

Page 28: ...start calibration language user ID method start self test date method time date checksum time format time start MANUAL input power off time cut off start BARCODE input concentration batch no run no next serial no calibration staus 090814 print scan mode start scan start scan ...