16
EN
QUICK SPA
QCC CLG30 RGBW - REV001B
CONNECTION DIAGRAM
DRIVING C
ABLE
PO
WER BUS C
ABLE
PO
WER BUS C
ABLE
DRIVING C
ABLE
PO
WER BUS C
ABLE
PO
WER BUS C
ABLE
20-30VDC
QCC-PLT 300
CLG 30 RGBW system - control from DMX control device
DMX COMMAND
SIGNAL
QCC-PLT 300*
This is an essential electronic device to man-
age the CLG RGBW by using a bus with two
wires for supplying power and the control
signal to the CLG QCC RGBW drivers.
Not included in the package.
Consult the QCC-PLT300 manual for
instructions to properly use the device.
WIRING DIAGRAM
Power
bus
wiring
Power
bus
wiring
1
2
3
4
5
6
7
8
9
G
Driving
cable
wiring
1 2 3 4 5 6 7 8 9 G
WARNING: DO NOT CONNECT DIRECTLY TO THE POWER
LINE (220VAC).
WARNING: DO NOT CONNECT DIRECTLY TO THE ON-BOARD
ELECTRICAL SYSTEM*.
WARNING: position the power supply box in an area clear of flam-
mable gases or vapors.
Undo the 4 screws of the cover to reach the driver. Connect the cables
as shown in the internal adhesive label threading them through the spe-
cific cable outlets.
For the POWER BUS connection use a cable having a size suitable for
charge. We recommend a 2x2.5 mm
2
cable.
The POWER BUS connection has no polarity.
The cable is not included in the package.
Make all the connections to the junction box containing the driver fol-
lowing the instructions shown in the sticker affixed to the internal cover
of the box.
JUNCTION BOX
WITH INTERNAL
DRIVER
JUNCTION BOX
WITH INTERNAL
DRIVER
CABLE OUTLET
TWO CABLES BUS
(POWER BUS)
TWO CABLES BUS
(POWER BUS)
CONNECTION DIAGRAM
INTERNAL SIDE OF JUNCTION BOX COVER WITH
‘WIRING DIAGRAM’ ADHESIVE LABEL.
SCREW
EACH QCC-PLT 300
CAN DRIVE UP TO
10 CLG30 RGBW
QCC CLG30
RGBW
QCC CLG30
RGBW
DMX512
CONTROL DEVICE