14.LED lighting White LED (lower side), Red LED (upper side) (with adjustable brightness)
15. Paste Precision
±
0.025mm
16.Paste force 1.5N
17.Power Supply 220V/230V AC
、
50/60HZ
、
3500
5.2 Technical Parameter
Main Interface
:
TL: Melting temperature of the solder
T1: starting temperature of heat preservation in the reflow soldering process
T2: ending temperature of heat preservation in the reflow soldering process
T3: Peak value temperature of the soldering and de-soldering process
T0: Valve temperature: The least temperature of the top heater in top heater heating process. T0<TB1
TIR
:
The setting temperature of bottom heating tubes
TB: The real temperature of bottom heater
TC: The real time temperature of Top Heater
TB1
:
The setting temperature of bottom heater before T2
TB2
:
The setting temperature of bottom heater after T2
KTB
:
The real temperature of bottom sirocco heater
KIR
:
The real temperature of bottom Infrared heater
IRT
:
The real temperature of IR sensor inspecting
S0: Heating time from T0 to T1
S1: Heating time from T1 to T2
S2: Heating time from T2 to T 3
S3: Heating preservation time of T3
TOS
:
select the using sensor
(
to select between IR and KT1-KT5
)
TYP
:
select solder flow or de-solder flow
(
DESO
,
SOLD
)
CUF
:
select the current process
(
0-9 ten processes
)
TOH
:
Top heater in working mode or not
BOH
:
Bottom sirocco heater in working mode or not
IRO
:
Outside parts of the Bottom Infrared heating tube in heating state or not
IRI
:
Inside parts of the bottom Infrared heating tube in heating state or not
BUM
:
Pump is in working mode or not
FAN
:
Top cooling fan in working mode or not
HED
:
the position of the top heater
(
UP-DOWN-UNKN
)
ALG
:
the position of the contraposition arm
(
IN-OUT-UNKN
)
SUC
:
the position of the nozzle
(
UP-DOWN-UNKN
)
TIM
:
Showing the count down time
CST
:
Starting temperature of one step in the whole process
CSE
:
Ending temperature of one step in the whole process