Parameter no. 12.
–
auto on timer relay
Defines the time after which the device's relay is turned to last known state.
Values (size is 2-byte dec):
•
Default value 0
•
0
–
disabled
•
30
–
32535 = 30
–
32535 seconds after which the device turns on
Parameter no. 13.
–
auto off timer relay
Defines the time after which the device's relay is turned to last known state.
Values (size is 2-byte dec):
•
Default value 0
•
0
–
disabled
•
30
–
32535 = 30
–
32535 seconds after which the device turns off
Parameter no. 30.
–
restore state on power failure
Values (size is 1-byte dec):
•
Default value 1
•
1
–
enabled (the device will restore state on power failure)
•
0
–
disabled (the device will not restore state on power failure and will remain off)
Parameter no. 31.
–
restore relay state on power failure
Values (size is 1-byte dec):
•
Default value 1
•
1
–
enabled (the device will restore state on power failure)
•
0
–
disabled (the device will not restore state on power failure and will remain off)
Parameter no. 40
–
Watt Power Consumption Reporting Threshold for Load
Choose by how much power consumption needs to increase or decrease to be reported. Values
correspond to percentages so if 10 is set (by default), the device will report any power
consumption changes of 10 % or more compared to the last reading.
Values (size is 2-byte dec):