EN
.
38
12.6.
Notification Command Class
The Luxy Smart Switch supports the following notification types and events:
Notification Type
Notification Event
Siren (0x0E)
Siren active (0x01)
Power Management (0x08)
Over-load detected (0x08)
Siren
The device sends a NOTIFICATION_REPORT, with the listed type and event, when it receives a
NOTIFICATION_REPORT.
The device can behave in one of two ways:
•
When it receives a
NOTIFICATION_REPORT(notificationType=0x08=POWER_MANAGEMENT) the device will
start blinking with a yellow color.
•
When the device receives any other NOTIFICATION_REPORT, if will start blinking with a
red color.
The device will continue to do so, until the user puts it back into its default state, which can be
done either with Z-Wave command or by physically touching the buttons of the device, so that a
change of output state occurs. There is some control of this behaviour, described in the
configuration parameters no. 3.
When the device receives notification report with State Idle (0x00), it will change state to Idle and
stop signalizing alarmed state (LEDs stop blinking).
Power Management
In case of exceeding the power value set in parameter 70 Overload safety switch (default 2300 W)
for more than 5 seconds, the Luxy Smart Switch automatically turns off the output and the
overload notification is sent (0x08 Over-load detected).
In case the parameter 70 is disabled the Luxy smart switch has a fixed overload safety value of
2400 W to prevent any damage to the module. In this case if the active power is greater than 2400
W for 5 seconds or more, the output is turned off automatically and the overload notification is
sent (0x08 Over-load detected).