Supported loads
Electric motor
Apply cos
φ
for calculation of max. Current. Max current
for cos
φ
=0,4 is 2 A at 250 VAC. In case of inductive loads
it is recommended to use RC snubber circuit.
Conventional incandescent
and halogen lights
LED bulb, compact
fluorescent bulb (CFL), low
voltage halogen bulbs with
electronic transformer
LED: 0,5A per channel
CFL*
LVH Electronic transformer: 2,4A per channel
Low voltage halogen bulbs
with conventional
transformer
*
Other type of loads
*
* Please contact Qubino support regarding marked load types:
http://qubino.com/support/#email