background image

Outdoor Remote 

Control Outlet

Model No.: ZAP 1FX

Questions or Concerns?

(855) 686-383

5 • suppo

[email protected]

Thank You.

Thank you for purchasing the ZAP 1FX Outdoor Remote

Control Outlet by Etekcity. We are dedicated to providing

our customers with quality products for building a better

living. Should you have any questions or concerns about

using your new product, feel free to reach out to our helpful

customer support team at (855) 686-3835 or by email

at [email protected]. We hope you enjoy your new

product!

Package Contents

1 x 

R

emote Contr

ol Outl

et

1 x 

R

emote Control

1 x 12V/23A Battery
1 x U

ser Manual

Safety Information

IMPORTANT:

 Plea

s

e read and c

omply with all 

o

f the 

in

structions and warnings p

ro

vided in this manual b

e

f

ore 

using the p

r

oduc

t. F

ailu

re to c

omply with the instructions 

and 

warnings p

ro

vided he

rein may re

sult in ina

cc

u

rate 

re

sul

t

s and

/

or damage 

t

o the p

r

oduct i

t

s

el

f

.

Important Safety Information

 

The wireless range may be shortened by other

electronic devices, appliances, walls, and other physical

barriers.

This outlet is intended for outdoor use, but can also be

used indoors.

Avoid exposing the outlet to moisture.

DO NOT exceed the maximum load current of 10A

(approximately 1200W).

DO NOT use appliances such as refrigerators, air

conditioning units, and washing machines with the

outlet. Such appliances exceed the maximum load

current of 10A (1200W).Keep out of reach of children.

To avoid overheating, this outlet is best used in areas

with proper air circulation.

For your safety, make sure the batteries within the

remote is correctly installed before use.

DO NOT dispose any part of this product in a fire.

The remote is not compatible with rechargeable

batteries.

This device is not intended for use in areas with high

humidity, such as bathrooms.

For best results, regularly change the battery in the

remote control.

If the remote is not in use for an extended period of

time, remove the battery from the remote.

Discard all parts of this product in accordance with

local environmental regulations. Do not dispose in

regular household waste.

This outlet is not compatible with the ZAP 3VX, 5LX,

5LX-S remote outlets, or with older remote-controlled

outlet models.

Function Diagram

1. 

Outl

et

2.  Po

w

er / Pr

og

ram B

u

tton

3. 

Outl

et Indicat

or Lig

ht

4. 

R

emote control

5. 

On 

B

u

tt

ons

6. 

Off 

B

u

tt

ons

7.  Battery Com

p

artment

2

4

5

6

3

1

7

Operation

T

he outl

e

t is p

r

e-p

r

og

rammed 

f

or immediat

e us

e

, but the 

con

figu

ration c

an be 

c

us

tomized to meet y

our needs

.

1. 

In

s

tall one 12V/23A 

b

attery into the remote control.

2. 

Plug the outl

et int

o a p

o

w

ered 

s

ocket.

Reprogramming an Outlet

1. 

Unplug d

e

vi

c

e f

r

om the outl

et.

2.  Pre

ss and hold the p

r

og

r

amming bu

tt

on u

ntil the 

indicat

or lig

ht 

s

tart

t

o blink.

1

3

1

1

3

3

2

4

2

2

4

4

p

re

ss

and

hold

3. 

Plug an applian

ce into e

ach outl

et. 

Keep the applian

ce 

swi

tch t

o ‘ON’ in o

rder to allo

w the outl

et to control the 

de

vi

ce.

4.  Pre

ss the ‘ON’ or ‘OF

F

’ bu

tton 

f

or the corre

sponding 

letter on the remote.

3. 

R

elea

se the p

r

og

r

am bu

tt

on, press the "ON" or "OFF" 

button for the desired number on the remote. 

4.  P

airing is su

cce

ssful when the indi

cat

or lig

ht 

s

to

ps 

blinking.

 The indicator 

lig

ht on the corre

sponding

 

outl

et 

will 

t

urn on, 

con

firming that the outl

e

t is n

o

w in us

e.

NOTE: 

Y

ou m

ay r

ep

eat the r

e-p

r

og

r

amming s

te

ps 

to a

ssign 

up 

t

o 10 outl

et

t

o a single l

etter t

o simul

t

aneously 

control 

multiple d

e

vi

ce

s with a single click.

Resetting an Outlet

To remo

ve an outl

e

t f

rom all remote control 

pairings:

1. 

Unplug a

ny de

vi

ce

connected to the remot

e outl

et.

R

emo

ve the outl

e

t f

r

om the p

o

w

er 

s

ocket.

2.  Pre

ss and hold the p

r

og

r

am bu

tton.

3. 

Plug the outl

et 

b

ack int

o the p

o

w

er 

s

ocke

t while 

con

tinuing 

t

o hold the p

r

og

r

am bu

tton.

4.  Pr

og

ram re

s

e

t will be 

c

ompl

et

e when the indi

cat

or lig

ht 

s

to

ps blinking.

p

re

ss

and

hold

CAUTION: To Reduce the Risk of Electric Shock – Use Only 

Indoors.

ATTENTION: Pour réduire le risque de choc électrique - 

Utiliser uniquement à l'intérieur

CAUTION: Risk of Electric Shock. Do not plug into another 

relocatable power tap or an extension cord.

ATTENTION: Risque de choc électrique. Ne le branchez pas 

sur un autre robinet d'alimentation relogable ou sur une 

rallonge.

CAUTION: Use only in dry locations

ATTENTION: Utiliser uniquement dans des endroits secs

FCC

 

ID:2AB22-ZAP1FXT

FCC

 

ID:2AB22-ZAP1FXT

Reviews: