Integration Note

Manufacturer: 

GE 

Model Number(s): 

Concord 4 (600-1040) 

Core Module Version: 

4.0 (Build 1463 and later) 

Comments: 

Factory Code 197.1414, System Number 006040, System Level 0501 

Document Revision Date: 

1/30/2013 

O

VERVIEW AND 

S

UPPORTED 

F

EATURES

 

The 

GE Concord 

panels integrate with the 

g!

 system using an RS-232 serial connection.  The Concord 

requires the 

SuperBus 2000 Automation Module (60-783-02)

 in order to integrate with 

g!

Integration of the security system provides monitoring and control from any touch screen, telephone or 
computer both locally and remotely.  Additionally, events occurring in the security system can trigger 
system commands in other sub-systems in the home. For example, a burglar alarm can turn all the lights 
on and send out email alerts.  The security system can also receive commands as a result of events 
within other sub-systems. For example, changing the house mode from Home to Vacation can trigger a 
security command to arm the system. 

T

HESE PANELS SUPPORT THE FOLLOWING FEATURES

Arm – Disarm:

 Arm and disarm from the Viewer interface is supported. Status information is available for 

all partitions. 

Auto Arm:

 Arming as a System Command from the Event Mapper is supported.  By default, automatic 

arming is enabled in the Configurator. 

Zone Status:

 Zone status information is available for all zones (in any partition), and is properly shown in 

the Viewer. 

History View:

 The history view is properly supported on any Viewer. 

Auto Zone and Partition Detection

: The 

g!

 system will automatically detect the zone name and number 

as well as partition name and number. 

Zone Bypass:

  Faulted zones may be bypassed to allow arming. 

 

Note:  

Due to the Concord panels programming, bypassing a faulted zone can only be done after the 

“Arm” command has been sent. 

 

Note:

 The GE Concord panel may not be compatible for control via all 

g!

 system controllers. Please 

contact ELAN support for assistance or use an alternate connection method. 

 

T

HESE PANELS DO NOT SUPPORT THE FOLLOWING FEATURES

Any feature not specifically noted as supported should be assumed to be unsupported. 

 

Reviews: