Parameter no. 10 - Activate / deactivate ALL ON/ALL OFF Functionality
Flush 2 Relay device responds to commands ALL ON / ALL OFF that may be sent by the primary
or secondary gateway (hub) within the Z-Wave network.
Values (size is 2 byte dec):
•
default value 255
•
255 - ALL ON active, ALL OFF active
•
0 - ALL ON not active, ALL OFF not active
•
1 - ALL ON not active, ALL OFF active
•
2 - ALL ON active, ALL OFF not active
Parameter no. 11 - Turn Load 1 (Q1) Off Automatically with Timer
If Load 1 (Q1) is ON, you can schedule it to turn OFF automatically after a period of time defined
in this parameter. The timer is reset to zero each time the device receives an ON command,
either remotely (from the gateway (hub) or associated device) or locally from the switch.
Values (size is 2 byte dec):
•
default value 0
•
0 - Auto OFF Disabled
•
1 - 32535 = 1 - 32535 seconds (or milliseconds
–
see Parameter no. 15). Auto OFF timer
enabled for a given amount of seconds (or milliseconds).
Summary of Contents for Flush 2 relay
Page 17: ...EN 17 4 Package Contents Flush 2 Relay Device Installation Manual...
Page 24: ...EN 24 After Qubino installation...
Page 25: ...EN 25 3 WAY INSTALLATION WITH 2 SWITCHES CONTROLLING THE SAME LIGHT Before Qubino installation...
Page 26: ...EN 26 After Qubino installation when power line and load line are in the same switch box...
Page 27: ...EN 27 After Qubino installation when power line and load line are in different switch boxes...
Page 28: ...EN 28 Before Qubino installation Where there is no neutral line N in switch box...
Page 29: ...EN 29 After Qubino installation Where there is no neutral line N in switch box...
Page 36: ...EN 36 Step 5 Turn the fuse on Step 6 Re include the device to your network...
Page 37: ...EN 37 Step 7 Start using the temperature sensor in connection with your device...