EN
.
48
Parameter no. 41
–
Watt Power Consumption Reporting Threshold for Q2 Load
Choose by how much power consumption needs to increase or decrease to be reported. Values
correspond to percentages so if 10 is set (by default), the device will report any power
consumption changes of 10% or more compared to the last reading.
Values (size is 1 byte dec):
•
default value 50
•
0 - Power consumption reporting disabled
•
1 - 100 = 1% - 100% Power consumption reporting enabled. New value is reported only
when Wattage in real time changes by more than the percentage value set in this
parameter compared to the previous Wattage reading, starting at 1% (the lowest value
possible).
NOTE: Power consumption needs to increase or decrease by at least 1 Watt to be reported,
REGARDLESS of percentage set in this parameter.
Parameter no. 42
–
Watt Power Consumption Report Time Threshold for Q1 Load
Set value refers to the time interval with which power consumption in Watts is reported (0
–
32535 seconds). If 300 is entered (by default), energy consumption reports will be sent to the
gateway (hub) every 300 seconds (5 minutes).
Values (size is 2 byte dec):
•
default value 300
•
0 - Power consumption reporting disabled
•
1 - 32535 = 1 - 32535 seconds. Power consumption reporting enabled. Report is sent
according to time interval (value) set here.
Summary of Contents for Flush 2 relay
Page 17: ...EN 17 4 Package Contents Flush 2 Relay Device Installation Manual...
Page 24: ...EN 24 After Qubino installation...
Page 25: ...EN 25 3 WAY INSTALLATION WITH 2 SWITCHES CONTROLLING THE SAME LIGHT Before Qubino installation...
Page 26: ...EN 26 After Qubino installation when power line and load line are in the same switch box...
Page 27: ...EN 27 After Qubino installation when power line and load line are in different switch boxes...
Page 28: ...EN 28 Before Qubino installation Where there is no neutral line N in switch box...
Page 29: ...EN 29 After Qubino installation Where there is no neutral line N in switch box...
Page 36: ...EN 36 Step 5 Turn the fuse on Step 6 Re include the device to your network...
Page 37: ...EN 37 Step 7 Start using the temperature sensor in connection with your device...