The BERT can be enabled, but not running, in the case of a time, bit, or error count limit.
An asterisk '*' after the error rate column indicates that the data is inverted. If the display is continuous and a time,
bit, or error limit is set with repeating gating, the display shows the end of the test by displaying '>>>' in the first
three columns.
The following shows an example display with a five (5) second repeating test.
E R Time Bit Count Error Count Error Rate
# ! 0:00:00:03.772 3.773e+07 2 5.301e-08*
# ! 0:00:00:04.023 4.023e+07 2 4.971e-08*
# ! 0:00:00:04.276 4.276e+07 2 4.677e-08*
# ! 0:00:00:04.527 4.528e+07 2 4.417e-08*
# ! 0:00:00:04.779 4.780e+07 2 4.184e-08*
>>> 0:00:00:05.000 5.000e+07 2 4.000e-08*
# ! 0:00:00:00.251 2.512e+06 0 0.000e+00*
# ! 0:00:00:00.503 5.032e+06 0 0.000e+00*
# ! 0:00:00:00.757 7.574e+06 2 2.641e-07*
# ! 0:00:00:01.011 1.011e+07 2 1.978e-07*
# ! 0:00:00:01.263 1.264e+07 2 1.582e-07*