Compact RDMS
TM
Telemetry Receiver
34
Quasonix, Inc.
Mnemonic
Name
Description
BE [c] T n
Set Bit Error
Measurement Type
Sets bit error measurement type
The test type can be configured to run continuously or stop
when either a time limit, bit count, or error count has been
reached. The error count limit guarantees a minimum number
of errors.
[c] is optional and indicates channel 0 or 1
If channel is omitted, the current tracking channel (TC)
is
used
If TC is 2, a channel number is required
T indicates type
where 'n' is one of the following:
C = continuous (clears limits)
T x = time limit
where 'x' is between 0 and 4.06
seconds
B x = bit limit
where 'x' is between 0 and 9.3825E+13
E x = error limit
where 'x' is between 0 and 3.1275E+13
BE G n
Set Bit Error
Measurement Gating
Sets bit error measurement gating
The test can be configured to make a single measurement or,
when a time limit, bit count, or error count is set, automatically
repeat the test.
Examples:
BE G S
S indicates Single
BE G R
R indicates Repeat