Compact RDMS
TM
Telemetry Receiver
8
Quasonix, Inc.
Mnemonic
Name
Description
Option (s)
Required
Basic or
Advanced
Command
Mode
Restriction
AV
Manual
Attenuator
Control
Report or set the value of the
input attenuator
Valid range is 0 to 124 dB
Examples:
AV
Report the input
attenuator setting
AV 0
Set input attenuator
to 0 dB
AV 124 Set input attenuator
to 124 dB
Standard Basic
None
BE
Bit Error Rate
For Bit Error Rate
commands and information,
refer to Appendix A, Bit Error
Rate Testing.
Standard
Advanced
Command
None
BL
Break Lock
Breaks false locks
No additional parameters
Standard Basic
PSK
(legacy)
BM
Bit Rate
Measurement
Report bit rate measurement
Standard
Basic
PSK
(legacy)
BR Bit
Rate
Report or set baseband bit
rate
Examples:
BR
Report the bit rate
setting
BR 5
Set bit rate to 5
Mbps
BR 0.6 Set bit rate to 600
Kbps
Standard Basic
For Asynch
PSK
(legacy)
modes, BR
A and BR
B must be
specified
separately
CC
Convolutional
Decoder
Enable
Enables or disables the
convolutional decoder
Examples
CC Report
convolutional
decoder state
CC 0
Set the convolutional
decoder to Disabled
CC 1
Set the convolutional
decoder to Enabled
K7 Basic PSK