3
rd
Generation Dual Channel
Compact RDMS
TM
Telemetry Receiver-Combiner
75
Quasonix, Inc.
•
Randomization – Enable or disable IRIG 106 15-bit randomization, as shown in Figure 105;
not
recommended for PN15 data
, due to potential conflict between the sequence generator and the randomizer,
both of which are based on the same generator polynomial
Figure 105: Data Generator, Randomization Drop Down Menu
5.4.15.3 BERT
The Bit Error Rate Tester (BERT) option, shown in Figure 106, allows the user to measure system performance. It
does this by comparing received data to a specified data pattern and counting the ratio of errored bits to total
received bits. This may be useful for various forms of system testing, including transmitter or receiver RF integrity
verification. The Browser provides the ability to set BERT parameters and access BERT status information.
Figure 106: Test Utilities, BERT
5.4.15.3.1 BERT Settings
The available BERT settings are: Measurement, (Re)Start BERT, Pattern, Type, Time Limit (s), Bit Limit, Error
Limit, Gating, and Restart on Resync. Each setting is described in this section.
•
Measurement – Enables or disables Bit Error Rate (BER) measurement