3
rd
Generation Dual Channel
Compact RDMS
TM
Telemetry Receiver-Combiner
59
Quasonix, Inc.
Figure 73: Monitor Screen, Mod Scaling Set to Track
The Mod Scaling indicator on the Monitor screen displays Track.
If there are two channels, and the Combiner is set to On, the Modulation Scaling controls for setting the modes are
linked. In Acquire or Track mode, the actual scaling operation functions independently in each channel.
5.4.12.1.2 Modulation Scaling
– Hold
When the RDMS™ has a good lock on the target transmitter, Modulation Scaling should be set to Hold by selecting
the Hold option on the Advanced PCMFM Settings Window, Modulation Index Scaling Mode drop down menu, as
shown in Figure 74.
When Modulation Scaling is set to Hold, the Mod Scaling indicator on the Monitor screen displays Hold, as shown
in Figure 75, indicating the optimal modulation index is set.
Figure 74: Advanced PCMFM Settings Menu, Modulation Scaling
– Hold