DLT VS160 Tape Drive Installation and Operations Guide
81-81191-01 Rev A01
January 2004
4-3
Indicator Activity During Normal Operation: Fault/Clean/Media
LEDs
The Fault, Clean, and Media LEDs indicate the status of the tape drive. Note that the LEDs can
indicate more than one of the indicated operating conditions simultaneously; for example:
•
If cleaning is required while a DLT1 (VS80) format data cartridge is loaded, both the Clean and
Media LEDs are on.
•
If an internal write/read diagnostic fails as a result of a permanent write error, both the Fault and
Clean LEDs blink slowly.
Table 4-2
describes the meaning of each front panel indicator.
See
Chapter 5, “Troubleshooting Your Tape Drive,”
for details on error conditions.
Table 4-2.
Fault / Clean / Media LED Activity and Tape Drive Status
Indicator
Activity
Operating Condition
Fault
Slow Blink (1x per second)
User-initiated write/read diagnostic failed.
Fast Blink (3x per second)
Servo or mechanism error.
On
Internal firmware error.
Clean
Slow Blink (1x per second)
Calibration error or permanent write/read error.
Medium Blink (2x per second)
Cleaning in progress.
On
Cleaning required: 250 tape motion hours
exceeded since last cleaning.
Media
Slow Blink (1x per second)
Unsupported format, or damaged or unsupported
data cartridge type inserted into the tape drive.
On
DLT1 (VS80) format DLTtape IV data cartridge
loaded.
Summary of Contents for ValueLoader DLT VS160
Page 1: ......
Page 4: ...iv January 2004 81 81191 01 Rev A01 Notes...
Page 8: ...Table of Contents viii January 2004 81 81191 01 Rev A01 Notes...
Page 10: ...List of Figures x January 2004 81 81191 01 Rev A01 Notes...
Page 12: ...List of Tables xii January 2004 81 81191 01 Rev A01 Notes...
Page 36: ...Chapter 3 Installing Your Tape Drive 3 20 January 2004 81 81191 01 Rev A01 Notes...
Page 58: ...Chapter 5 Troubleshooting Your Tape Drive 5 12 January 2004 81 81191 01 Rev A01 Notes...
Page 59: ......